期刊文献+

低剂量、大螺距双源CT前瞻性心电门控冠状动脉成像在心房颤动患者中的初步应用 被引量:8

Application of low-dose, high-pitch spiral acquisition dual-source CT coronary angiography in patients with atrial fibrillation
暂未订购
导出
摘要 目的评价第二代双源CT大螺距前瞻性心电门控扫描模式(fllash spiral)在房颤患者中应用的可行性。方法从我院接受大螺距双源CT冠状动脉成像检查的1077例患者中,选择房颤患者10例,分别采用HP前瞻性心电门控扫描(flash spiral模式)和回顾性心电门控模式扫描(spiral模式)。Flash spiral模式采集图像时间选择为RR间期的20%-30%成像。结果10例患者均采用flash模式扫描,其中7例患者图像质量好(评分1分),3例患者有轻度伪影,但可评价血管(评分2分)。SpirM扫描中,4例病例右冠状动脉伪影重,为非诊断血管病例,1例回旋支重度伪影。Flash模式扫描有效射线剂量为O.680-1.887mSv,8例患者低于1mSv。Spiral扫描有效射线剂量为14.920-21.306mSv。结论①房颤患者采用大螺距flash spiral模式单个心动周期成像可获得良好的效果,且图像质量优于回顾性心电门控模式。②由于RR间期不规则,房颤患者flash spirM扫描时必须在下一个R波前完成扫描,需提前采集数据时间(RR间期的20%-30%采集为最佳)。③房颤患者flash spiral扫描有效射线剂量低于1mSv。 Objective The objective was to attempted to investigate whether high-pitch spiral acquisitiondual-source CTCA can be performed in patients with atrial fibrillation at low dose. Methods Ten patients with AF who were admitted for a first diagnostic coronary angiogram were screened for participation. All patients underwent dual-source CT. Patients were performed CTCA using the prospectively ECG-gated high-pitch mode and retrospective ECG gating spiral acquisition respectively with their permissions. The start phase for image acquisition of the most cranial slice was selected at 20%-30% of the R-R interval in all patients. Results Image qualities of prospectively ECG-gated high-pitch mode were rated as being excellent in 7 cases of all the patients and only 3 cases image qualities were graded score2. By using retrospective ECG gating spiral acquisition mode. Non-diagnostic image quality (score3) occurred in 4 patients which were observed in RCA and 1 patient in LCX. The estimated radiation dose ranges from 0.680 to 1.887 mSv in flash mode and the radiation dose of spiral mode were very high ranging from 14.920 to 21.306 mSv. Conclusion Our case series suggest that patients with atrial fibrillation rhythm can be performed CTCA with high-pitch spiral acquisition mode. 20%-30% of the RR interval window for data acquisition for high-pitch dual'source CTCA may probably obtain good image quality with low doses.
出处 《中国心血管病研究》 CAS 2011年第9期651-655,共5页 Chinese Journal of Cardiovascular Research
基金 内蒙古科学技术基金项目(20110054)
关键词 第二代双源CT 大螺距 冠状动脉造影 心房颤动 Dual-source CT High pitch Coronary angiography: Atrial fibrillation
  • 相关文献

参考文献12

  • 1Donati OF,Burg MC,Desbiolles L,et al.High-pitch 128-slice dual-source CT for the assessment of coronary stents in a phantom model.Academic radiology,2010,17:1366-1374.
  • 2Hausleiter J,Bischoff B,Hein F,et al.Feasibility of dual-source cardiac CT angiography with high-pitch scan protocols.Journal of cardiovascular computed tomography,2009,3:236-242.
  • 3Goetti R,Feuchtner G,Stolzmann P,et al.High-pitch dual-source CT coronary angiography:systolic data acquisition at high heart rates.European radiology,2010,20:2565-2571.
  • 4Leschka S,Stolzmann P,Desbiolles L,et al.Diagnostic accuracy of high-pitch dual-source CT for the assessment of coronary stenoses:first experience.European radiology,2009,19:2896-2903.
  • 5Achenbach S,Marwan M,Ropers D,et al.Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition.Eur Heart J,2010,31:340-346.
  • 6Austen WG,Edwards JE,Frye RL,et al.A reporting system on patients evaluated for coronary artery disease.Report of the Ad Hoc Committee for Grading of Coronary Artery Disease,Council on Cardiovascular Surgery,American Heart Association.Circulation,1975,51:5-40.
  • 7Karlo C,Leschka S,Goetti RP,et al.High-pitch dual-source CT angiography of the aortic valve-aortic root complex without ECG-synchronization.European radiology,2010,21:205-212.
  • 8European Commission.European Guidelines on Quality Criteria for Computed Tomography.Report EUR 16262.
  • 9Scheffel H,Alkadhi H,Leschka S,et al.Low-dose CT coronary angiography in the step-and-shoot mode:diagnostic performance.Heart,2008,94:1132-1137.
  • 10Ropers U,Ropers D,Pflederer T,et al.Influence of heart rate on the diagnostic accuracy of dual-source computed tomography coronary angiography.J Am Coll Cardiol,2007,50:2393-2398.

二级参考文献23

  • 1毛新波,朱新进,陈涛,曾惠良,陈学光.16层螺旋CT冠状动脉成像技术分析[J].中国心血管病研究,2005,3(8):600-602. 被引量:10
  • 2谢培怡,许秀娟,姚宇玫,李静芝,沈盛晖,茅国群,陈瑶.多层螺旋CT诊断急性冠脉综合征的临床价值[J].中国心血管病研究,2006,4(11):820-822. 被引量:4
  • 3Lell M,Marwan M,Schepis T,et al.Prospectively ECG-triggered high-pitch spiral acquisition for coronary CT angiography using dual source CT:technique and initial experience.Eur Radiol JT-European radiology,2009,19:2576-2583.
  • 4Goetti R,Baumuller S,Feuchtner G,et al.High-pitch dualsource CT angiography of the thoracic and abdominal aorta:is simultaneous coronary artery assessment possible?AJR Am J Roentgenol JT-AJR.American journal of roentgenology,2010,194:938-944.
  • 5Kim SY,Seo JB,Do KH,et al.Coronary artery anomalies:classification and ECG-gated multi-detector row CT findings with angiographic correlation.Radiographics JT-Radiographics:a review publication of the Radiological Society of North America,Inc,2006,26:317-333.
  • 6Castorina S,Privitera G,Luca T,et al.Detection of coronary artery anomalies and coronary aneurysms by multislice computed tomography coronary angiography.Ital J Anat Embryol,2009,114:77-86.
  • 7Reimann AJ,Rinck D,Birinci-Aydogan A,et al.Dual-source computed tomography:advances of improved temporal resolution in coronary plaque imaging.Invest Radiol,2007,42:196-203.
  • 8Bastarrika G,Arraiza M,Arias J,et al.Dual-source CT coronary angiography:image quality and optimal reconstruction interval.Radiologia,2009,51:376-384.
  • 9Muhlenbruch G,Seyfarth T,Sco CS,et al.Diagnostic value of 64-slice multi-detector row cardiac CTA in symptomatic patients.Eur Radiol,2007,17:603-609.
  • 10Schuijf JD,Mollet NR,Cademartiri F,et al.Do risk factors influence the diagnostic accuracy of noninvasive coronary angiography with multislice computed tomography? J Nucl Cardiol,2006,13:635-641.

共引文献4

同被引文献78

  • 1孙凯,韩瑞娟,马利军,王利军,王志清,赵冬梅,王刚.大螺距双源CT前瞻性心电门控冠状动脉成像在高心率患者中的应用[J].中华临床医师杂志(电子版),2011,5(17):4962-4967. 被引量:3
  • 2孙凯,韩瑞娟,马利军,王利军,李立刚,陈九宏.心房颤动患者的低剂量、大螺距双源CT冠状动脉成像的可行性研究(英文)[J].中华临床医师杂志(电子版),2011,5(20):6027-6032. 被引量:1
  • 3王继琛,邱建星,王鹤,高莉,孙晓伟,侯振亚,蒋学祥.心电图编辑软件在CT冠状动脉成像中的应用价值[J].中国医学影像技术,2006,22(10):1485-1488. 被引量:21
  • 4赵坤,时季成,邵广瑞,张伟,宋磊.64层螺旋CT冠状动脉成像质量影响因素的分析[J].医学影像学杂志,2007,17(7):687-691. 被引量:12
  • 5Kovacs A,Probst C,Sommer T. CT coronary angiography in patients with atrial fibrillation[J].Rofo,2005.1655-1662.
  • 6Marwan M,Pflederer T,Schepis T. Accuracy of dual-source computed tomography to identify significant coronary artery disease in patients with atrial fibrillation:comparison with coronary angiography[J].{H}EUROPEAN HEART JOURNAL,2010.2230-2237.
  • 7Achenbach S,Goroll T,Seltmann M. Detection of coronary artery stenoses by low-dose,prospectively ECG-triggered,high-pitch spiral coronary CT angiography[J].JACC Cardiovasc Imaging,2011.328-337.
  • 8Alkadhi H,Stolzmann P,Desbiolles L. Low-dose,128-slice,dual-source CT coronary angiography:accuracy and radiation dose of the high-pitch and the step-and-shoot mode[J].{H}HEART,2010.933-938.
  • 9Achenbach S,Marwan M,Ropers D. Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition[J].{H}EUROPEAN HEART JOURNAL,2010.340-346.
  • 10Karlo C,Leschka S,Goet i RP. High-pitch dual-source CT angiography of the aortic valve-aortic root complex without ECG-synchronization[J].{H}European Radiology,2011.205-212.