摘要 目的评价Bactec MGIT 960系统自临床标本分离分枝杆菌的价值。方法收集临床标本共578份,分别接种于BactecMGIT 960系统和改良罗氏培养基,分离到的分枝杆菌用荧光PCR进行菌种鉴定。结果 578份临床标本中,共分离出171株分枝杆菌(29.6%)。两种方法均阳性有105株,仅Bactec MGIT 960系统阳性有54株,仅罗氏培养基阳性有12株。BactecMGIT 960系统分离率为27.5%(159/578),罗氏培养基法为20.2%(117/578)。Bactec MGIT 960系统法阳性平均报告时间为10.2 d,罗氏培养基法为27.5 d。Bactec MGIT 960系统法污染率为7.6%,罗氏培养基法为4.3%。结论 Bactec MGIT 960分枝杆菌检测技术是一种较好的快速分离分枝杆菌的方法,联合改良罗氏培养基可进一步提高分离率。
出处 《临床检验杂志》 CAS CSCD 北大核心 2011年第5期396-397,共2页 Chinese Journal of Clinical Laboratory Science
  • 相关文献

参考文献6

  • 1结核病诊断细菌学检验规程[J].中国防痨杂志,1996,18(1):28-31. 被引量:803
  • 2Rodrigues C, Shenai S, Sadani M, et al. Evaluation of the BACTEC MGIT 960 TB system for recovery and identification of Mycobacterium tuberculosis complex in a high through put tertiary care centre [ J ]. Indian J Med Microbiol,2009,27 ( 3 ) :217-221.
  • 3Rishi S, Sinha P, Malhotra B, et al. A comparative study for the de- tection of mycobacteria by BACTEC MGIT 960, Lowenstein Jensen media and direct AFB smear examination [ J ]. Indian J Med Microbi- ol,2007,25(4) :383-386.
  • 4Alcaide F, Benitez MA, Escriba JM, et al. Evaluation of the BACTEC MGIT 960 and the MB/BacT systems for recovery of myeo- bacteria from clinical specimens and for species identification by DNA AccuProbe [ J ]. J Clin Microbial, 2000, 38 ( 1 ) : 398-401.
  • 5陈军,王飞,任易,肖勇,彭孝红.BacT/Alert 3D系统与罗氏培养基分离分枝杆菌的比较[J].中国防痨杂志,2007,29(2):151-153. 被引量:18
  • 6Hillemann D, Richter E, Rusch-Gerdes S. Use of the BACTEC My- cobacteria Growth Indicator Tube 960 automated system for recovery of mycobacteria from 9558 extrapulmonary specimens, including u- rine samples[J]. J Clin Microbiol, 2006,44( 11 ) :4014-4017.

二级参考文献6

  • 1结核病诊断细菌学检验规程[J].中国防痨杂志,1996,18(1):28-31. 被引量:803
  • 2Schmidt RM,Rosenkranz HS.Antimicrobial activity of local anaesthetics:lidocaine and procaine[J].J Infect Dis,1970,121(6):597-607
  • 3Piersimoni C,Scarparo C,Callegaro A,et al.Comparison of MB/Bact alert 3D system with radiometric BACTEC system and Lowenstein-Jensen medium for recovery and identification of mycobacteria from clinical specimens:a multicenter study[J].J Clin Microbiol,2001,39(2):651-657
  • 4Mirovic V,Lepsanovic Z.Evaluation of the MB/BacT system for recovery of mycobacteria from clinical specimens in comparison toLowensteinJensen medium[J].Clin Microbiol Infect,2002,8(11):709-714
  • 5Harris G,Rayner A,Blair J,et al.Comparison of three isolation systems for the culture of mycobacteria from respiratory and non-respiratory samples[J].J Clin Pathol,2000,53(8):615-618
  • 6吴龙章,蔡杏珊,潘美玉,曹务华,曹智忠,黄进晖.BacT/ALERT3D全自动培养仪在细菌鉴定和药敏试验的临床应用[J].中华检验医学杂志,2002,25(4):243-244. 被引量:25

共引文献818

同被引文献75

引证文献9

二级引证文献48

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部