期刊文献+

抽气碰撞法回收擦拭样品上铀微粒方法 被引量:4

Vacuum Suction-Impact Collection for Recovering Uranium Particles From Swipe Sample
在线阅读 下载PDF
导出
摘要 建立了一种回收微粒的新方法——抽气碰撞法。擦拭布上的铀微粒通过抽气碰撞装置回收到导电胶上,用于二次离子质谱仪(SIMS)对微粒的同位素丰度比测量。使用扫描电镜(SEM)寻找和统计擦拭布和导电胶上的微粒数目,计算装置的回收率。该装置对核孔膜上直径为0.5~20.0μm的铅微粒回收率为(43±5)%,擦拭布上铀微粒回收率约为48%,回收微粒的分散性好。制备的样品可直接用于SIMS测量,SIMS对235 U与238 U同位素丰度比的测量值为0.007 25±0.000 09,测量标准偏差小于3%。 A new particle recovery method from safeguards swipe samples was developed for subsequent isotope ratio analysis of uranium particles by secondary ion mass spectrometry(SIMS).The particles were determined and counted by scanning electron microscope(SEM).The recovery efficiency is about(43±5)% for PbO particles and about 48% for uranium particles respectively.The dispersion of recovery particles is satisfied.The samples prepared by this method were measured by SIMS.The average isotope ratio of 235U/238U for individual natural uranium particles is 0.007 25±0.000 09 with a standard deviation less than 3%.
出处 《原子能科学技术》 EI CAS CSCD 北大核心 2011年第1期112-116,共5页 Atomic Energy Science and Technology
关键词 微粒回收率 抽气碰撞法 二次离子质谱仪 同位素丰度比 particle recovery efficiency vacuum suction-impaction secondary ion mass spectrometry isotope ratio uranium
  • 相关文献

参考文献7

  • 1DONOHUE D L.Strengthening IAEA safeguards through environmentalsamplingand analysis[J].J Alloys Compd,1998,11:271-273.
  • 2DONOHUE D L.Strengthened nuclear safeguards[J].Anal Chem,2002,74:28A-35A.
  • 3TAMBORINI G,BETTI M,FORCINA V,et al.Application of secondary ion mass spectrometry to the identification of single particles of uranium and their isotopic measurement[J].Spectrochimica Acta:Part B,1998,53:1289-1302.
  • 4ESAKA F,WATANABE K,FUKUYAMA H,et al.Efficient isotope ratio analysis of uranium particles in swipe samples by total-reflection Xray fluorescence spectrometry and secondary ion mass spectrometry[J].J Nucl Sci Technol,2004,41(11):1 027-1 032.
  • 5RUEDENAUER F,KUNO Y,DONOHUE D,et al.SIMS particle analysis at the IAEA safeguards analytical laboratory[C]//Proceedings of INMM 42nd Annual Meeting.Indian Wells,USA:[s.n.],2001.
  • 6MAIOROV V,CIURAPINSKI A,RAAB W,et al.Screening and radiometric measurement of environmental swipe samples[C]//Proceedings of IAEA Symposium on International Safeguards.Vienna:IAEA,2001.
  • 7RUEDENAUER F,HEDBERG M,PICHLMAYER F.Comtamination effects and quality control for the IAEA/SAL secondary ion mass spectrometer,CL.A-2444[R].Vienna:IAEA Safeguards Analytical Laboratory,2000.

同被引文献58