期刊文献+

Vitallium 2000铸造支架可摘局部义齿的临床应用 被引量:16

Clinical use of removable partial dentures of Vitallium 2000 casting frame
暂未订购
导出
摘要 背景:Vitallium 2000引入中国较晚,鲜有临床应用报道。目的:观察Vitallium 2000铸造支架可摘局部义齿的应用效果。方法:选择大连市口腔医院修复科进行可摘局部义齿修复患者67例,采用精密铸造技术,用Vitallium 2000材料进行铸造支架可摘局部义齿修复,制作修复体86件,采用患者自我评价和口内检查的方式,在义齿使用一两年后,对义齿的使用情况进行随访。结果与结论:支架义齿适应快,舒适,稳固,咀嚼有力且无异味。口腔检查提示义齿固位及咬合关系良好,口腔黏膜基本正常,基牙无松动和继发龋。失败病例中1例戴牙后反复压痛,重新制作,人工牙和基托控制咬合力后使用良好;在半年和1年后的复查中,共出现3例基牙牙周炎,通过牙周治疗,2个月后复查,牙周良好。提示Vitallium 2000铸造支架可摘局部义齿临床疗效良好。 BACKGROUND: As late introduction to China, Vitallium 2000 has been rarely reported. OBJECTIVE: To observe the clinic effect of Vitallium 2000 as framework material in removable partial denture. METHODS: Eighty-six Vitallium 2000 framework removable partial dentures were used for 67 patients, clinical examination were carried out from 1 to 2 years, and the condition of abutment and the performance of dentures were recorded based on self-evaluation and intraoral examination. RESULTS AND CONCLUSION: The removable partial dentures with Vitallium 2000 framework are comfortable and good as well as its masticatory function and retention, and they especially can be designed for some free-end clinical cases. In the study, one case of repeated tenderness underwent re-produced denture, and the artificial tooth and denture base had a good bite force; in 6 months and 1 year re-examination, a total of three cases presented with abutment periodontitis, and they were all recovered at 2 months following periodontal treatment. Vitallium 2000 framework removable partial dentures have a good clinical effect.
出处 《中国组织工程研究与临床康复》 CAS CSCD 北大核心 2011年第29期5486-5488,共3页 Journal of Clinical Rehabilitative Tissue Engineering Research
  • 相关文献

参考文献4

二级参考文献19

  • 1冯海兰.口腔修复学[M].北京:北京大学医学出版社,2007:168-180.
  • 2Karlsen K, Owall B. Construction proposals for vitallium prostheses [J]. Quintessenz Zahntech, 1975, 1 (2) : 19-24.
  • 3Taylor RM. Vitallium removable overlays for deep overbite-ease report[J]. N Z Dent J, 1985, 81(363):28-29.
  • 4Bridgeport DA, Branfley WA, Herman PF. Cobalt-chromium and nickel-chromium alloys for removable prosthodontics. Part 1: Mechanical properties[J]. J Prosthodont, 1993, 2(3):144-150.
  • 5Pienkos TE, Morris WJ, Gronet PM, et al. The strength of multiple major connector designs under simulated functional loading [J]. J Prosthet Dent, 2007, 97 (5):299-304.
  • 6Knapp JG, Shotwell JL, Kotowicz WE. Technique for recording dental casturveyor relations[J]. J Prosthet Dent, 1979, 41 (3): 352-354.
  • 7Knapp JG, Small IA. Fixed mandibular complete denture prostheses supported by mandibular staple bone plate implant[J]. J Prosthet Dent, 1990, 63 (1) : 73-76.
  • 8Knapp JG,Shotwell JL, Kotowicz WE. Technique for recordingdental cast-surveyor relations. J Prosthet Dent, 1979, 41 ( 3 ) : 352-354.
  • 9Knapp JG, Small IA. Fixed mandibular complete denture prostheses supported by mandibular staple bone plate implant. J Prosthet Dent, 1990,63 ( 1 ) : 73-76.
  • 10冯海兰.口腔修复学.北京:北京大学医学出版社,2007.

共引文献63

同被引文献128

引证文献16

二级引证文献53

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部