R134a和R417A应用于热泵热水器灌注式替代R22的实验分析 被引量:9

Experimental Analysis of R134a and R417A Applied to Heat Pump Water Heaters for the ‘Drop-in’ Substitution of R22
在线阅读 下载PDF
导出
摘要 在空气源热泵热水器中,对R22、R417A和R134a进行了理论计算及实验分析。结果表明,R417A的制热量和COP更接近于R22,并且排气温度比R22低25℃左右,排气压力也比R22平均低0.17MPa;尽管R134a也具有较低的排气温度和排气压力,但其制热量远远小于R22,低温工况下,吸气压力过低,而且需更换压缩机润滑油,因此,R417A比R134a更适合在空气源热泵热水器中对R22进行直接灌注式替代。 The theoretical calculation and experimental analysis of R22,R417 and R134a were carried out in air source heat pump water heaters.The results show that the heating capacity and COP of R417A are close to R22 compared to R134a and the discharge temperature is 25 degrees lower than R22,the discharge pressure is also 0.17MPa lower than R22 on average.Although R134a possesses lower discharge temperature and pressure,its heating capacity is much less than R22.The suction pressure of R134a is very low under low temperature condition,and the lubricating oil has also to be replaced.Therefore,R417A is the more suitable ‘drop-in’ candidate than R134a to substitute R22 in air source heat pump water heaters.
机构地区 上海理工大学
出处 《制冷学报》 CAS CSCD 北大核心 2011年第4期43-47,62,共6页 Journal of Refrigeration
关键词 热工学 空气源热泵热水器 R417A R134A R22 灌注式替代 Pyrology Air source heat pump water heaters R417A R134a R22 ‘Drop-in’ substitution
  • 相关文献

参考文献4

二级参考文献11

  • 1[3]J.D.Douglas,J.E.Braum,E.A.Groll,D.R.Tree.A cost-based method for comparing alternative refrigerants applied to R22 system. International Journal of Refrigeration,1999,22:107~125
  • 2[6]Gallagher J.S, Mclinden M O, Morrision G.Thermodynamic Diagrams for Refrigerant Mixtures. ASHRAE Trans,1988, 95:2119~2134
  • 3董天禄.离心式/螺杆式制冷机组及应用[M].机械工业出版社,2001.10.
  • 4Roberts N A.Use of R417A (ISCEON 59) in Refrigeration and Air Conditioning Appliancations[J/OL].http:∥www.eurocooling.com/articlerhodia.htm.
  • 5郭永兴.R417A冷媒替代R22冷媒之应用现况∥Rhodia报告,1990.
  • 6Chambers O R,Roberts N A.The development of a low temperature blend of R125,R134a with either R600 or R600a[J/OL].http:∥www.centrogalileo.it/nuovaPA/Articoli%20tecnici/INGLESE%20CONVEGNO/rhodia.doc.
  • 7Arpea C,Mastrullo R,Renno C.An analysis of the performance of a vapor compression plant working both as a water chiller and a heat pump using R22 and R417A.Applied Thermal Engineering,2004,24:487-499.
  • 8Arpea C,Renno C.Experimental comparison of R22 with R417A performance in a vapor compression refrigeration plant subjected to a cold store.Energy Conversion and Management,2004,45:1807-1819.
  • 9蒋能照.HCFC22替代技术的进展[J].有机氟工业,1997(3):8-10. 被引量:3
  • 10谷波,李文华.R22三种替代物R134a、R410a和R407c在空调系统中性能对比研究[J].流体机械,1999,27(10):41-42. 被引量:27