摘要 脉冲式激光测距仪原理简单,集成化和小型化较好,但测量精度较低,或精度高设计难度大。本文采用单片机的CTMU技术,提出了一种高精度测距的实现方法。文中介绍了CTMU的原理及与AD转换单元连接、CTMU进行时间测量的原理、CTMU测距仪的分辨率分析、脉冲激光测距的更长动态范围设计。实验结果表明,该设计结构简单,体积小,数据采集精度高,电路输出的分辨率为1分米,输出恒定可靠,该实验方案给实际测量带来很大的方便。 Impulse laser range finder has a simple theory,good integration and miniaturization.But the accuracy is low or high precision design is difficult,This paper gives a high-precision ranging implementation using CTMU technology of PIC.The paper introduces the CTMU principle and connection with the AD unit,the time measurement principl of CTMU,CTMU rangefinder resolution analysis,the design of a longer dynamic range of pulsed laser ranging.Experimental results show that the design of simple structure,small size,high accuracy data acquisition,' circuit output resolution of 1 decimeter,the output constant and reliable.The actual measurement of the experimental program to bring great convenience.
出处 《激光杂志》 CAS CSCD 北大核心 2011年第4期50-51,共2页 Laser Journal
基金 常州信息职业技术学院2007年度院级项目<小型高精度激光测距仪>(2007Z-11)
关键词 CTMU 激光测距 时间测量 CTMU Laser ranging time measurement
  • 相关文献

参考文献4

二级参考文献37

  • 1丁建国,沈国保,刘松强.基于数字延迟线的高分辨率TDC系统[J].核技术,2005,28(3):173-175. 被引量:14
  • 2赵欣,戚俊,涂碧海,陈结祥,张毅,李季,刘建国,赵平建.激光测高系统中基于GP1的飞行时间测量[J].量子电子学报,2007,24(1):96-99. 被引量:2
  • 3孙杰,潘继飞.高精度时间间隔测量方法综述[J].计算机测量与控制,2007,15(2):145-148. 被引量:85
  • 4吴刚,李春来,刘银年,戴宁,王建宇.脉冲激光测距系统中高精度时间间隔测量模块的研究[J].红外与毫米波学报,2007,26(3):213-216. 被引量:44
  • 5Acam Mess-electronic INC. Solutions in time precision time interval measurement, http://www, acam. de/fileadmin/Download/pdf/others/DB_GP2_cn, pdf,2007.
  • 6Araki T. Optical distance meter using a short pulse width laser diode and a fast avalanche photodiode[J]. Rev Sci Instrum,1995,66(1) :43-47.
  • 7Palojrvi P, Ruotsalainen T, Kostamovaara J. A new approach to avoid walk error in pulsed laser rangefinding[J]. IEEE Intern Sympos on Cireu and Systems Pro,1999,34(21) :256 261.
  • 8K Maatta,J Kostamovaara. A high-precision time-to-digital converter for pulsed time-to-flight laser radar applications[J].IEEE Trans.Instr.and Meas.,1998.47(2):521-536.
  • 9T Araki.Optical distance meter using a short pulse width laser diode and a fast avalanche photodiode[J].Rev.Sci.Instrum.,1995,66(1):43-47.
  • 10P Palojrvi,T Ruotsalainen,J Kostamovaara.A new approach to avoid walk error in pulsed laser rangefinding [J].IEEE Intern.Sympos.on Circu.and Systems Pro.1999,I-258-I-261.