期刊文献+

气浮—磁分离工艺处理含油废水 被引量:12

Treatment of Oily Wastewater by Flotation-Magnetic Separation Process
在线阅读 下载PDF
导出
摘要 采用气浮—磁分离工艺处理某石化企业的含油废水,重点考察了磁分离单元的工艺条件对除油率的影响。实验结果表明磁分离单元的最佳工艺条件为:絮凝剂聚合氯化铝加入量25 mg/L,磁种加入量100 mg/L,磁场强度40 mT,搅拌条件为先以150 r/min的转速搅拌2 min,再以50 r/min的转速搅拌5 min。在最佳工艺条件下进行气浮—磁分离工艺除油实验,在进水油质量浓度平均为29.5 mg/L时,气浮单元出水油质量浓度平均为8.5 mg/L,除油率平均为71.1%;磁分离单元出水油质量浓度平均为4.7 mg/L,除油率平均为44.1%;总除油率平均为83.8%。 The oily wastewater of a petrochemical enterprise was treated by flotation -magnetic separation process. The effects of the process conditions in the magnetic separation unit on the oil removal rate were studied especially. The optimum process conditions are as follows: flocculant PAC dosage 25 mg/L, magnetic seed dosage 100 mg/L, magnetic field strength 40 mT, stirring time 2 min with 150 r/min of rotation speed, stirring time 5 rain with 50 r/min of rotation speed. Under theses conditions, and when the average oil mass concentration of the influence is 29.5 mg/L, the average oil mass concentration of the effluent from the flotation unit is 8.5 mg/L with 71. 1% of oil removal rate, and that of the effluent from the magnetic separation unit is 4.7 mg/L with 44.1% of oil removal rate. The average total oil removal rate is 83.8 %.
出处 《化工环保》 CAS CSCD 北大核心 2011年第4期342-345,共4页 Environmental Protection of Chemical Industry
关键词 磁分离 磁种 气浮 絮凝 除油 废水处理 magnetic separation magnetic seed flotation flocculation oil removal wastewater treatment
  • 相关文献

参考文献12

二级参考文献121

共引文献204

同被引文献159

引证文献12

二级引证文献71

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部