摘要
由于误操作使碱窜入低压蒸汽系统,导致20号碳钢的377mm×10mm管线对接焊缝发生苛性应力腐蚀破裂。
The caustic ran into low steam system because of mistake operation.And made the butt weld of 20# carbon steel 377mm pipeline occure caustic stress corrosion crack.The occured reasons are analized in this article.
出处
《石油化工设备技术》
CAS
1999年第4期52-54,共3页
Petrochemical Equipment Technology