摘要 对一起家庭火灾进行现场勘查,通过对楼梯口附近隔断、墙面、地面的勘查,排除其首先起火的可能性后,确定火灾为顶棚内电线短路引起。通过现场勘验过程,归纳总结了顶棚起火的特征及现场勘查中应该注意的问题,如起火点在火灾初期会迅速转移,误导勘验人员;顶棚起火必须有电器线路在火灾前处于通电状态的证据等。 Fire scene investigation was made to a home fire,the possibility of fire occurring on partition,wall and floor near the gateway of staircase was excluded by fire investigation,and it was identified that fire was induced by line short circuit inside of ceiling.By fire scene investigation,characteristic of ceiling fire and the key points were concluded,such as fire ignition would move at early stage of fire,which would mislead fire investigators,and it must be indentified that line was electrified before ceiling fire.