高效液相色谱法同时测定人血阿莫西林钠/克拉维酸钾血药浓度 被引量:1

Simultaneous determination of serum concentrations of amoxicillin and clavulanate potassium in human blood using high-performance liquid chromatography
暂未订购
导出
摘要 目的建立阿莫西林钠/克拉维酸钾人血药浓度的色谱分析方法。方法采用对乙酰氨基酚为内标,人血浆样品用甲醇沉淀蛋白后高速离心进样;色谱柱:C18色谱柱(依利特Hypersil BDS,5μm,4.6mm×150mm);流动相:乙腈-0.05mmol/L磷酸盐缓冲液=10∶90(V/V,磷酸调pH至2.3);紫外检测波长:220nm;流速:1.0ml/min;柱温:25℃。结果克拉维酸钾、阿莫西林钠及内标物对乙酰氨基酚保留时间分别为5.3、7.2、8.5min,人血浆中内源性杂质对目标物的测定没有干扰。阿莫西林钠在0.524.16μg/ml范围线性良好(r2=0.9996),克拉维酸钾在0.2662.14μg/ml范围线性良好(r2=0.9998);阿莫西林钠和克拉维酸钾的最低检测浓度分别为0.065和0.066μg/ml。;阿莫西林钠的相对回收率分别为95.9%96.5%(n=5),克拉维酸钾的相对回收率分别为92.5%98.8%(n=5),阿莫西林钠日内RSD为1.84%6.4%,日间RSD为2.1%7.8%;克拉维酸钾日内RSD为3.57%8.6%,日间RSD为1.8%9.1%。结论本方法简便、准确、灵敏、特异性强、重现性好。 Objective To establish a chromatography-based method for simultaneous analysis of the concentrations of amoxicillin and clavulanate potassium in human blood. Methods With paracetamol as the internal control, human plasma samples, after treatment with methanol for protein sedimentation and centrifugation, were loaded for analysis with high-performance liquid chromatography (HPLC). HPLC analysis was carried out using a C18 column (5 μm, 4.6 mm×150 mm) with the mobile phase of acetonitrile-PBS (0.05 mol/L) of 10∶90 (pH 2.3), UV detection wavelength of 220 nm, flow rate of 1.0 ml/min, and column temperature of 25 ℃. Results The retention time of acetaminophen for potassium clavulanate, amoxicillin sodium and the internal control was 5.3, 7.2, and 8.5 min, respectively, and no interference by the endogenous impurities in the plasma samples was found. Amoxicillin sodium showed a good linearity within the concentration range of 0.52-4.16 μg/ml (r2=0.9996), and potassium clavulanate had a good linearity within the range of 0.266-2.14 μg/ml (r2=0.9998). The minimum detectable concentrations of amoxicillin sodium and potassium clavulanate were 0.065 μg/ml and 0.066 μg/ml, respectively. The relative recoveries of amoxicillin sodium were 95.9%-96.5% (n=5), and those of clavulanate potassium were 92.5%-98.8% (n=5); the intra- and inter-day RSD of amoxicillin sodium was 1.84%-6.4% and 2.1%-7.8%, as compared to that of potassium clavulanate of 3.57%-8.6% and 1.8%-9.1%, respectively. Conclusion This method is simple, accurate, sensitive, specific and reproducible for analyzing the concentrations of amoxicillin and clavulanate potassium simultaneously in human plasma
出处 《南方医科大学学报》 CAS CSCD 北大核心 2011年第6期1069-1071,共3页 Journal of Southern Medical University
基金 广东省科技计划(2008B030301172)
关键词 阿莫西林钠/克拉维酸钾 高效液相色谱法 血药浓度 同时测定 amoxicillin/clavulanate potassium HPLC serum concentration determination simultaneous
  • 相关文献

参考文献4

二级参考文献9

共引文献29

同被引文献14

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部