期刊文献+

泵站止回装置结构性能分析及现场试验研究

The structural behavior analysis and field trial study of pumping station check device
在线阅读 下载PDF
导出
摘要 止回装置改造是泵站更新改造过程中的重要组成部分,其结构性能直接对泵站的安全运行及泵站装置的效率等产生重要影响。文章选取止回装置部分改造过的某泵站进行现场试验,通过对不同机组的流量、电流、电压、拍门开度及拍门关闭时的振动和噪声等参数进行现场测试,对比分析了泵站常用3种止回装置相应机组的效率、振动噪声及能耗情况,发现新型止回装置在某些方面优于传统悬挂式拍门,对泵站止回装置部分的更新改造具有借鉴意义。 The transformation of check device is an essential ingredient in the improvement process of pumping station, the structural behavior of check device produce significant influences for the safety and efficiency of the pumping station.This pump station that check device is partly transformed was chose to planed field trial in this paper, lhrough the field test, such as the parameters of flow, electric current, voltage, the opening of flap, the vibration and noise generated by the close of flap were obtained.The contrast and analysis of ef- ficiency, vibration noise and energy consumption belongs to these three kinds of check devices shows that the new type is better than traditional suspension flap in some respects.The comparative conclusion of this paper could provide references for the transformation and renovation of check devices.
出处 《企业技术开发》 2011年第4期26-28,共3页 Technological Development of Enterprise
关键词 泵站试验 止回装置 振动 效率 能耗 the test of pumping station check devices vibration efficiency energy consumption
  • 相关文献

参考文献6

二级参考文献3

  • 1张意.节能型自由侧翻式拍门[J].中国水利,2007(1):69-69. 被引量:4
  • 2GB/T50265-97.泵站设计规范[S].[S].,..
  • 3水资源与水电工程科学国家重点实验室.自由侧翻式拍门结构和水力特性研究[J].2006.

共引文献107

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部