High Frequency Transformers for DC/DC Converter Used in Solar PV System
High Frequency Transformers for DC/DC Converter Used in Solar PV System
摘要
This paper presents and investigates planar and coaxial high frequency power transformers used for DC/DC converters in a three phase photo voltaic (PV) power systems. The winding structure including a Faraday shield between the primary and secondary windings is designed to minimize eddy current losses, skin and proximity effects, and to reduce the leakage inductance, and the inter winding coupling capacitance. Finite Element Method is employed to analyze the magnetic flux and eddy current distributions. The two different kinds of prototype high frequency transformers are designed and tested. The simulation and experiment results are demonstrated and compared with non-shielded transformers. The shielded transformers have achieved the expected results with a relatively small coupling capacitance, compared with the conventional high frequency transformer. This shield decreases the inter-winding coupling capacitance Cps. The topology of this shield has to be such that it acts as a Faraday screen while avoiding eddy current generation.
参考文献17
-
1B. Burger, W. Roth, Solar inverters-market, technology and trends, in: 7th International PCIM China Conference, Mar. 2008, pp. 17-24.
-
2J. Lu, S. Stegen, D. Butler, High frequency and high power density transformers for DC/DC converter used in a solar PV system, in: Proceedings of IEEE PEDG 2010, Hefei, China, June 16-18, 2010.
-
3M.H. Kheraluwala, D.W. Novotny, D.M. Divan, Coaxially wound transformers for high-power high-frequency applications, IEEE Trans. on Power Electronics 7 (1) (1992) 54-62.
-
4K. Yamaguchi, S. Ohnuma, T. Imagawa, J. Toriu, H. Matsuki, Characteristics of a thin film microtransformer with circular spiral coils, IEEE Trans. Magn. 29 (5) (1993) 2232-2237.
-
5J. Lu, F. Dawson, S. Yamada, Analysis of high frequency planar sandwich transformers for switching converters, IEEE Trans. Magn. 31 (1995) 4235-4237.
-
6S. Stegen, J. Lu, Shielding effect of high frequency power transformers for DC/DC converter used in solar PV systems, in: Proceedings of APEMC 2010, Beijing, Apr., 2010.
-
7K.W. Klontz, D.W. Novotny, D. Divan, An active cooled 120kW coaxial winding transformer for fast charging electric vehicles, IEEE Trans. on Industry Applications 31 (6) (1995) 1257-1263.
-
8J. Lu, F.P. Dawson, S. Yamada, Application and analysis of adjustable profile high frequency switch mode transformer having a U-shaped winding structure, IEEE Trans. on Magnetics 34 (4) (1998) 3186-3188.
-
9J. Lu, High frequency coaxial winding transformer with heat sink and Faraday shielding, Australian provisional patent, 2006905991, 2010.
-
10J. Lu, F. Dawson, Analysis of Eddy current distribution in high frequency coaxial transformer with faraday shield, IEEE Trans. on Magnetics 42 (10) (2006) 3171-3173.
-
1长征.非晶变压器的节能效果[J].金属功能材料,2002,9(3):43-43. 被引量:1
-
2袁丹青,王培培,王利伟,王玲玲,潘科.屏蔽泵谐波磁场的有限元分析[J].水电能源科学,2011,29(4):137-139.
-
3顾利.电动机护环的锻造[J].锻造与冲压,2011(4):48-50. 被引量:1
-
4黄慧春,胡仁杰.混合信号虚拟仪器的电磁兼容性设计[J].微计算机信息,2012(7):22-23.
-
5苏国梁,庞春,赵春刚.500kV变电所保护小室设计及抗干扰措施[J].中国电力,2003,36(12):45-48. 被引量:5
-
6赵志斌,崔翔,张波,李琳.应用矩量法计算变电站内的空间电磁场[J].中国电机工程学报,2004,24(11):148-153. 被引量:24
-
7B. Abdi M.H. Joukar A.H. Ranjbar A.A. Nasiri.The Effect of Leakage Inductance on High Frequency Transformer Harmonics[J].Journal of Energy and Power Engineering,2011,5(7):659-664.
-
8李淑敏.浅谈电磁屏蔽[J].电子材料与电子技术,2004,31(4):44-48.
-
9Ю.Н.Стародубцев,刘治平.完善电工钢的主要方向[J].武钢技术,1993,31(12):57-62.
-
10谈莹.高压试验厅的屏蔽设计[J].低压电器,2009(20):48-51. 被引量:2