期刊文献+

肾移植术前活体供肾的多层螺旋CT血管成像分析

Value of multislice spiral CT in preoperative assessment of living renal donors
暂未订购
导出
摘要 目的探讨多层螺旋CT血管成像(MSCTA)在活体肾移植术前的应用价值。方法 55例肾移植供体,其中男50例,女5例,平均31.10±6.08岁。采用德国西门子Emotion16排螺旋CT机。所有病例均行平扫、动脉期及静脉期扫描。结果 33例可见副肾动脉,发生率60.0%;7例可见肾动脉过早分支,发生率12.7%;7例有多支肾静脉,发生率12.7%;主动脉后位型肾静脉1例,肾静脉晚期汇合3例,2例可见左侧性腺静脉粗大、迂曲,2例右侧隔下动脉源自右侧肾动脉。结论 MSCTA能够明确肾移植供体的血管变异,可作为肾移植供体术前的首选影像学检查。 Objective To determine the value of multislice spiral CT for preoperative assessment of living renal donors. Methods Forty-five consecutive living kidney donors (50 men, 5 women; mean age, 31.10 ± 6.08 years) underwent 16-MDCT in the unenhanced, contrast-enhanced arterial and nephrographic phases. Results Vascular variations included accessory renal arteries (33), early branching of main renal arteries (7), multiple renal veins (7), retro-aortic renal vein (1), origin of right inferior phrenic artery from right renal artery (2), late venous confluence (3), and dilatation of left ovarian vein (2). Conclusion MSCTA is the first imaging method of choice before living kidney donor transplantation.
出处 《影像诊断与介入放射学》 2011年第2期90-94,共5页 Diagnostic Imaging & Interventional Radiology
关键词 活体肾 肾移植 体层影像术 X线计算机 血管成像 Kidney Living kidney Renal transplantation Tomography X-ray computed Angiography
  • 相关文献

参考文献16

  • 1彭谦,范淼,黄刚,李子平,叶滨宾.多层CT血管造影在活体肾移植供体术前的应用[J].中国临床医学影像杂志,2008,19(6):402-405. 被引量:20
  • 2Holden A,Smith A,Dukes P,et al.Assessment of 100 live potential renal donors for laparoscopic nephrectomy with multi detector row helical CT.Radiology,2005,237:973-980.
  • 3Singh AK,Sahani DV,Christopher R.Semiautomated MIP images created directly on 16-section multidetector CT console for evaluation of living renal donors.Radiology,2007,244:583-590.
  • 4Kawamoto S,Montgomery RA,Lawler LP,et al.Multi-detector row CT evaluation of living renal donors prior to laparoscopic nephrectomy.Radio Graphics,2004,24:453-466.
  • 5Rastogi N,Sahani DV,Michael A,et al.Evaluation of living renal donors:accuracy of three-dimensional 16-Section CT.Radiology,2006,240:136-144.
  • 6Türkvatan A,Akinci S,Yildiz S,et al.Multidetector computed angiography for preoperative evaluation of vascular anatomy in living renal donors.Surg Radiol Anat,2009,31:227-235.
  • 7赵殿江,马大庆,贺文,林俊.多层螺旋CT后处理图像对亲属活体供肾术前的综合评价[J].临床放射学杂志,2006,25(10):932-935. 被引量:12
  • 8张龙江,王联营,沈文,祁吉.多层螺旋CT对活体肾移植供体术前综合评价的初步研究[J].中国医学影像技术,2007,23(4):585-588. 被引量:8
  • 9Sahani DV,Rastogi N,Greenfield AC,et al.Multi-detector row CT in evaluation of 94 living renal donors by readers with varied experience.Radiology,2005,235:905-910.
  • 10诸静其,郝楠馨,常时新,汪波.64层螺旋CT观察双侧肾动脉解剖变异[J].中国医学影像技术,2009,25(10):1871-1874. 被引量:21

二级参考文献55

  • 1王小宁,俞同福,邹月芬,黄庆娟,王德杭,张炜.对亲体肾移植供肾者血管影像学诊断方法的评价[J].实用放射学杂志,2005,21(3):304-307. 被引量:10
  • 2彭令荣,韩希年.16层螺旋CT副肾动脉分析[J].中国医学计算机成像杂志,2006,12(2):109-112. 被引量:23
  • 3张鹏,李振龙,赵英杰.副肾动脉的多层螺旋CT评价[J].放射学实践,2006,21(7):709-711. 被引量:14
  • 4公佩友,耿军祖,邹振兴,王福江.肾动脉变异的16层螺旋CT表现[J].泰山医学院学报,2006,27(4):303-306. 被引量:22
  • 5孔玉祥,范松青,张宇新,等.人体局部解剖学.北京:人民卫生出版社,2008:171.
  • 6Tombul ST,Aki FT,Gunay M,et al.Preoperative evaluation of hilar vessel anatomy with 3-D computerized tomography in living kidney donors.Transplant Proe,2008,40(1):47-49.
  • 7Kawamoto S,Fishman EK.MDCT angiography of living laparoseopic renal donors.Abdom Imaging,2006,31 (1):361-373.
  • 8Raman SS,Pojchamamwiputh S,Muangsomboon K,et al.Utility of 16-MDCT angiography for comprehensive preoperative vascular evaluation of laparoscopic renal donors.AJR Am J Roentgenol,2006,186(6):1630-1638.
  • 9Singh AK,Sahani DV.Imaging of the renal donor and transplant recipient.Radiol Clin North Am,2008,46 (1):79-93.
  • 10Turkvatan A,Ozdemir M,Cumhur T,et al.Muhidetector CT angiography of renal vasculature:normal anatomy and variants.Eur Radiol,2009,19(1):236-244.

共引文献58

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部