期刊文献+

聚丙烯纤维对混凝土力学性能的影响 被引量:12

Impact on concrete's mechanical properties of polypropylene fiber
在线阅读 下载PDF
导出
摘要 通过聚丙烯纤维混凝土的力学试验,研究了聚丙烯纤维掺量对混凝土基本性能的影响。试验结果表明:聚丙烯纤维混凝土的抗压强度、劈拉强度均随纤维掺量的增加而降低,当掺量由0增加到1.2 kg/m3时,纤维混凝土7 d抗压、抗拉强度与基准混凝土相比,分别降低了11.4%和8.7%,28 d强度则分别降低了12.1%和3.6%,而混凝土抗冲击能力则提高了4.76倍;同时由于聚丙烯纤维的加入使得混凝土具有较高的韧性,对防止普通混凝土在荷载作用下的变形及裂缝的发生具有重要意义。 The influence of mix quantity of polypropylene fiber to the key property of concrete was studied based on the mechanical experiment of polypropylene fiber concrete.The test result indicated that both the compressive strength and the splitting tensile strength of polypropylene fiber concrete were reduced with the increase of the mix quantity of the fiber.When the mix quantity increased from 0 to 1.2 kg/m3,the 7 d resistant to compression and the tensile strength of the fiber concrete reduced by 11.4% and the 8.7% respectively comparing with those of the control concrete,the 28 d intensity of the fiber concrete reduced by 12.1% and 3.6% separately,but the anti-impact ability of concrete enhanced by 4.76 times.Moreover,the addition of the polypropylene fiber enabled a higher toughness of concrete,which is crucial to the prevention of deformation and cracks of normal concrete under loads.
作者 祝云华
机构地区 内江师范学院
出处 《水运工程》 北大核心 2011年第5期63-66,共4页 Port & Waterway Engineering
关键词 聚丙烯纤维 混凝土 力学性能 掺量 polypropylene fiber concrete mechanical property incorporation rate
  • 相关文献

参考文献7

二级参考文献30

  • 1邓宗才,李建辉,傅智,刘景园,王齐.聚丙烯纤维混凝土直接拉伸性能的试验研究[J].公路交通科技,2005,22(7):45-48. 被引量:27
  • 2伍章健,余寿文.界面性能对陶瓷基复合材料桥联增韧的影响[J].中国科学(A辑),1995,25(1):98-106. 被引量:1
  • 3黄晓明,张玉宏,李昶,邓松.水泥混凝土路面碎石化层应力强度因子有限元分析[J].公路交通科技,2006,23(2):52-55. 被引量:46
  • 4陈锋锋,黄晓明,秦永春.连续配筋混凝土路面横向裂缝分布模型的研究[J].公路交通科技,2006,23(6):18-21. 被引量:16
  • 5沈荣熹.低掺率合成纤维在混凝土中的作用机制.水泥基复合材料科学与技术[M].北京:中国建筑工业出版社,1999.
  • 6Zollo R F. Collated Fibrillated Polypropylene Fibres in FRC [A]. Fibre Reinforced Concrete International Symposium [C]. [S. l.]: ACI Special Publication, 1984: 397-409.
  • 7Alhozaimy A M, Soroushian P, Mirza F. Mechanical Properties of Polypropylene Fiber Reinforced Concrete and the Effects of Pozzolanic [J]. Cement and Concrete Composites, 1996(18): 85292.
  • 8Chan Y N, Luo X, Sun W. Compressive strength and pore structure of high-performance concrete after exposure to high tempera ture up to 800 ℃[J]. Cement and Concrete Research,2000,30(4) :247-251.
  • 9Zhang B, Bicanic N, Pearce C J, et al. Residual fracture properties of normal-and high-strength concrete subject to elevated temperature[J]. Magazine of Concrete Research,2000,52(2) :123-135.
  • 10Peter Shuttleworth. Fire protection of precast concrete tunnel linings on the channel tunnel rail link[J]. Concrete,2001, (4) :121-123.

共引文献109

同被引文献96

引证文献12

二级引证文献181

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部