期刊文献+

64排多层螺旋CT冠状动脉成像的临床应用 被引量:4

暂未订购
导出
摘要 有创的冠状动脉造影(invasive coronary angiography,ICA)一直被认为是诊断冠状动脉粥样硬化性心脏病(coronary artery disea,CAD)的"金标准",但这种创伤性检查在少数情况下会产生潜在的、可危及生命安全的并发症,且大量ICA检查只是用来排除CAD。随着多层螺旋CT(multi-slice spiral computed tomography,MSCT)硬件和软件技术的不断更新,其扫描速度快、损伤性小,
出处 《齐齐哈尔医学院学报》 2011年第4期566-569,共4页 Journal of Qiqihar Medical University
  • 相关文献

参考文献28

  • 1Ghersin E,Litmanovich D,Dragu R,et al.16-MDCT coronary angiogrsphy versus invasive coronary angiography in acute chest pain syndrome:a blinded prospective study[J].Am J Roentgenol,2006,186:177-184.
  • 2Plass A,Baumert B,Haussler A,et al.Sixteen-channel muhidetector row computed tomography versus coronary angiography in a surgical view[J].Heart Surg,Forum,2006,9:E572-E578.
  • 3Mollet NR,Cademarfitl F,Nieman K,et al.Muhislice spiral computed tomogsaphy cownary angiography in patients wifll stable mlgina pecmris[J].J Am Coll Cardiol,2004,43(12):2265-2270.
  • 4Mellet NR,Cademartifi F,Krestin GP.et al.Impmved diagnostic accuracy with 16-now multi-slice computed tomography[J].J Am Coll Cardiol,2005,45(1):128-132.
  • 5Leschka S,Alkedhi H,Plass A,et al.Aeemcy of MSCT comnary an-Giography with 64-slice technology:first experience[J].Eur heart J,2005,26(15):1482-1487.
  • 6Moiiet NR,Cademartiri F,van Mieghem CA,et al.High-resolution spiral computed tomography coronary angiography in patients referred for diagnostic eonventhional coronary angioraphy[J].Cirenlation,2005,112(15):2318-2323.
  • 7Stein PD,Beemath A,Kayali F,et al.Muldtidetector cornpukd tomography for the diagnosis of coronary artery disease:a systematic review[J].Am J Med,2006,119(3):203-216.
  • 8Becker C,Nikolaou K,Mudders M,et al.1% cker c,Nikohaou K,Ex vivo coronary athexosclerotic plaque characterization with muhi-detector-row CT[J].Eur Radiol,2003,13(9):2094-2098.
  • 9Leber AW,Knez A,Becket A,et al.Accuracy of muhidetector spiral computed tomography in idenifying and differentiating the composition of coronary atherosclerotic plaques:a comparative study with intracoronary ultrasound[J].J Am Coil Csrdiol,2004,43(7):1241-1247.
  • 10Leber AW,Knez A,Von Ziegler F,et al.Quantification of obstructive and nonohstructive coronary lesions by 64-slice computed tomography:a comparative study with quantitative coronary angiography and intravascular ultrasound[J].J Am cou Cardiol,2005,46(1):147-154.

二级参考文献76

  • 1朱清於 见:陈在嘉 高润霖主编.冠状循环的解剖学[A].见:陈在嘉,高润霖主编.冠心病[C].北京:人民卫生出版社,2002.6—7.
  • 2Ohnesorge B,Flohr T,Becker C,etal.Cardiac imaging by means of electrocardiographically gated multisection spiral CT:initial experience.Radiology,2000,217(2):564-571.
  • 3Nikolaou K,Flohr T,Knez A,etal.Advances in cardiac CT imaging:64-slice scanner.Int J Cardiovasc Imaging,2004,20(6):535-540.
  • 4Nieman K,Oudkerk M,Rensing BJ,etal.Coronary angiography with multi-slice computed tomography.Lancet,2001,357(9256):599-603.
  • 5Kopp AF,Schroeder S,Kuettner A,etal.Non-invasive coronary angiography with high resolution multidetector-row computed tomography.Results in 102 patients.Eur Heart J,2002,23(21):1714-1725.
  • 6Nieman K,Cademartiri F,Lemos PA,etal.Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography.Circulation,2002,106(16):2051-2054.
  • 7Ropers D,Baum U,Pohle K,etal.Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction.Circulation,2003,107(5):664-666.
  • 8Mollet NR,Cademartiri F,Nieman K,etal.Multislice spiral computed tomography coronary angiography in patients with stable angina pectoris.J Am Coll Cardiol,2004,43(12):2265-2270.
  • 9Leschka S,Alkadhi H,Plass A,etal.Accuracy of MSCT coronary angiography with 64-slice technology:first experience.Eur Heart J,2005,26(15):1482-1487.
  • 10Achenbach S,Moshage W,Ropers D,etal.Value of electron-beam computed tomography for the noninvasive detection of high-grade coronary-artery stenoses and occlusions.N Engl J Med,1998,339(27):1964-1971.

共引文献173

同被引文献22

引证文献4

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部