摘要
用双抗体夹心法建立人血清Ⅳ型胶原的ELISA检测法,方法快速、稳定,灵敏度为16ng/ml,批内变异系数为8.52%,批间变异系数为9.23%,回收率为95.28%,与间质胶原无交叉反应。测定110例健康成人血清Ⅳ型胶原浓度均值是34.36±19.41ng/ml。临床应用于96例肝纤维化及30例慢性肾功能不全患者血清Ⅳ型胶原浓度测定,其均值明显高于正常人浓度,有显著差异。
A sandwich type of enzyme - linked immunosorbent assay for serum human type tV collagen was established.The method is fast and stable.The sensitivity of the immunoassay was 16ng/ml. The CV value of intra-assayswas 8.52%,and that of inter - assays was 9.23% .The accuracy was 95.28%. No cross reaction was found with typeI collagen. The concentrations of serum Type IV collagen from 110 adult healthy persons were 34.36±19.41ng/ml.Serum samples from 96 patients with Liver cirrhosis and 30 patients with chronic renainsufficiency showedincreased value of serum Type tV collagen concentration compared with those from the healthy controls in avery significant degree.
出处
《重庆医科大学学报》
CAS
CSCD
1999年第4期340-343,共4页
Journal of Chongqing Medical University
关键词
Ⅳ型胶原
肝纤维化
肾功能不全
血清诊断
Type IV Collagen
Hepatic Fibrosis
Chronic Renal Insufficiency