期刊文献+

经食管超声多普勒与温度稀释法对心输出量测定的相关性研究 被引量:2

The correlation between transesophageal Doppler and thermodilution for cardiac output monitoring
原文传递
导出
摘要 目的 研究经食管超声多普勒和温度稀释法在心输出量监测中的相关性。方法  15例ASA ~ 级 ,择期在全麻下手术的病人 ,其中嗜铬细胞瘤切除术 2例 ,心脏瓣膜置换术 13例 ,采用经食管超声多普勒 ( TED)与温度稀释法 ( TD)同体配对测定心输出量 ,进行两种心输出量测定方法的相关性研究。结果 两种方法监测下 15例病人心输出量具有良好的相关性 ,相关系数为 0 .83 ,回归方程 ( TED) =1.0 8TD- 0 .2 5 ,偏离 ( bias)为 0 .11。心脏瓣膜置换术病人主动脉阻断前两种监测方法的相关系数为 0 .85 ,TDE=1.0 9TD- 0 .16,偏离为 0 .2 3 ,主动脉阻断后两种监测方法的相关系数为0 .77,TED=1.13 TD- 0 .72 ,偏离为 - 0 .0 4。结论 经食管超声多普勒是一种无创、简便、连续的测定心输出量的方法 ,与温度稀释法有良好的相关性。 Objective To evaluate the correlation between the methods of transesophageal Doppler (TED) and thermodilution (TD) for cardiac output (CO) Methods Fifteen ASA class Ⅱ Ⅲ patients receiving elective operation during general anesthesia,were included in this study,of which 13 patients underwent cardiac valve replacement operation CO was measured simultaneously by TED and TD methods Results There was a high correlation between the two methods in CO measurement (r=0 83,P<0 01),the regression equation was as follows:TED=1 08TD-0 25,bias:0 11 During pre clamping period in valve replacement operation,the correlation coefficient was 0 85,with the regression equation TED=1 09TD-0 16,bias:0 23 During post clamping period,the correlation coefficient was 0 77,with the regression equation TED=1 13TD-0 72,bias:-0 04 Conclusion TED is a noninvasive reliable method for measurement of CO during operation
出处 《中华麻醉学杂志》 CAS CSCD 北大核心 1999年第10期581-583,共3页 Chinese Journal of Anesthesiology
关键词 热稀释法 心排血量 经食管 超声多普勒 Thermodilution Cardiac output Transesophageal Doppler
  • 相关文献

同被引文献24

  • 1[2]Turlapety P,Vary R,Kaplan JA.Nicardipine,a new intravenous calcium antagonist:review of its pharmacology,pharmacokinetics,and perioperative applications.J Cardiothorac Anesth,1989,3:344-355.
  • 2[3]Hersey SL,O'Dell NE,Lowe S,et al.Nicardipine versus nitroprusside for controlled hypotension during spinal surgery in adolescent.Anesth Analg,1997,84:1239-1244.
  • 3[4]Baoguo Wang,Jun Tang,Paul F White,et al.Effect of the anesthetic technique used for maintaining hemodynamic stability on patient outcome after ambulatory surgery.Anesthesiology,1997,87(3A):A28.
  • 4Koobi T,Kaukinen S,Ahola T,et al.Non-invasive measurement of cardiac output: whole-body impedance cardiography in simultaneous comparison with thermodilution and direct oxygen Fick methods.Intensive Care Med,1997;23:1132~1137
  • 5Weil MH.Electrical bioimpedance for noninvasive measurement of cardiac output.Crit Care Med,1997;25:1455
  • 6Sageman WS,Amundson DE.Thoracic electrical bioimpedance measurement of cardiac output in postaortocoronary bypass patients.Crit Care Med,1993;21:1139~1142
  • 7Keyl C,Rodig G,Lemberger P,et al.A comparision of the use of transesophageal dopper and thermodilution techniques for cardiac output detemination.Eur J Anaesthesiol,996;3:36~142
  • 8Valtier B,holley BP,elot JP.Noninvasive monitoring of cardiac output in critically ill patients using transesophageal Doppler.Am J Respir Crit Care Med,998;58:7~83
  • 9Pierpont G,eber RE,an FK,et al.Continuous cardiac output monitoring in patients using transtracheal Doppler ultrasound.J Cardiavascul Tech,1990;9:31
  • 10Singer M,Allen MJ,Webb AR.Effects of alterations in left ventricular filling,contractility,and systemic vascular resistance on the ascending aortic blood velocity waveform of normal subjects.Crit Care Med,1991;19:1138~1145

引证文献2

二级引证文献42

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部