期刊文献+

环境水中化学需氧量的反向流动注射分析法研究 被引量:9

Study on Determination of COD in Natural Water\=by Reversed Flow Injection Analysis
在线阅读 下载PDF
导出
摘要 研究了Ce(SO4)2H2SO4体系反向流动注射分析法测定环境水中化学需氧量(COD)的试验条件。在2.5~160.0mg/L线性范围内,采样频率达到25/h,Cl-的质量浓度至2500mg/L无干扰。对60mg/L的标准试样重复测定11次,相对标准偏差为0.79%,检出下限为2.5mg/L。该法便于实际工作中COD的连续监测,用于河水、池塘水分析,获得结果与经典的重铬酸钾法相对照。 A system of Ce(SO4)2H2SO4 for determination of COD in natural water samples by reversed flow injection analysis is discussed. In the linear range of 2.5160.0 mg/L for COD concentration, the sampling frequency of 25/h is obtained. Up to 2500 mg/L of Cl- does not interfere with determination of COD. The detection limit of the method for COD is 2.5 mg/L. Precision of the determination for the sample with 60 mg/L of COD is 0.79% RSD (n=11). The method has been applied to the online determination of COD in river and pool water and the results are in agrecment with traditional method using potassium dichromate.\=\=
出处 《岩矿测试》 CAS CSCD 北大核心 1999年第3期185-188,共4页 Rock and Mineral Analysis
基金 甘肃省自然科学基金 甘肃省环保局科学技术资助
关键词 化学需氧量 反向流动注射分析 环境水 chemical oxygen demand(COD) reversed flow injection analysis natural water