期刊文献+

一种利用暂态电流行波的输电线路故障测距方法 被引量:44

A NOVEL METHOD FOR FAULT LOCATION OF TRANSMISSION LINES USING FAULT TRANSIENT CURRENT TRAVELLING WAVES
在线阅读 下载PDF
导出
摘要 提出了一种利用暂态电流行波的输电线路故障测距新方法。以同母线上任一“有限长”非故障线路作为参考线路,通过比较由故障线路暂态电流与该参考线路暂态电流形成的反向行波浪涌和对应的正向行波浪涌的极性,识别来自故障方向的行波浪涌,消除了来自参考线路的暂态行波浪涌的影响。EMTP仿真表明这种方法是可行的。 A novel method for fault location of transmission lines,using fault induced transient current travelling waves,is presented.The arbitrary sound line with 'finite length' is selected as a reference line,and the directional (forward and backward) travelling waves are constructed using the transient currents of the fault line and the reference line.The surges coming from the fault are identified by comparing the polarity of the backward surge,which is formed by the travelling wave of the transient current of the fault line and the travelling wave in the reference line,against the polarity of the corresponding forward surge.The effect of surges that come from the reference line is avoided.The feasibility of the novel method is proved by EMTP simulation.
出处 《电力系统自动化》 EI CSCD 北大核心 1999年第14期29-32,共4页 Automation of Electric Power Systems
基金 国家自然科学基金
关键词 暂态行波 输电线路 故障测距 线路保护 电力系统 power systems transient travelling waves transmission line fault location EMTP
  • 相关文献

参考文献14

二级参考文献19

  • 1王渝红,黄雯莹,任震,杨桦.离散二进小波变换及其在电机故障分析中的应用[J].电力系统自动化,1995,19(12):20-24. 被引量:20
  • 2董新洲.小波理论应用于输电线路故障测距研究:博士学位论文[M].西安:西安交通大学,1996..
  • 3湖北省电力试验研究所.平武系统继电保护的主要问题的措施[M].,1982..
  • 4陈平,硕士学位论文,1994年
  • 5徐丙垠,博士学位论文,1991年
  • 6贺家李,超高压输电线路故障分析与继电保护,1987年
  • 7董新洲,全国变电站综合自动化研讨会会议论文集,1995年
  • 8王广运,GPS精密测地系统原理,1988年
  • 9董新洲,中国电机工程学报,1997年,17卷,6期
  • 10程正兴(译),小波分析导论,1996年