基于RS-485总线的水轮机温度监测系统 被引量:8

RS-485 based hydroturbine temperature monitoring system
在线阅读 下载PDF
导出
摘要 利用TCD-48数字温度巡检仪、RS-485总线和PC机监控分析软件,构成了一个水轮机温度在线监测系统。TCD-48数字温度巡检仪能实现48路温度采集,直接读取各个测点温度值,并通过RS-485总线上送PC工控主机,进行数据显示、保存和后期分析。该系统针对实时传送的数据,加以数据拟合分析,实现了对水轮机本体各个组件的温度在线监测。通过实时监控,运行监控人员可以很快发现温度异常,并定位故障源。该系统适用于中小型水电站的水轮机温度监测。 An on-line hydroturbine temperature monitoring system is introduced,which is composed of a TCD-48 digital temperature inspection instrument,RS-485 bus and PC monitoring software.The TCD-48 digital temperature inspection instrument directly acquires the temperatures via 48 channels and sends the data to the industrial PC via RS-485 bus for data display,storage and analysis.The monitoring system carries out the fitting analysis based on the acquired data to realize the online temperature monitoring of hydroturbine components.The operator can find the temperature abnormality in real time and locate the fault quickly.The system is suitable for mid-and small-size hydropower stations.
作者 蒋政宏
出处 《电力自动化设备》 EI CSCD 北大核心 2011年第5期130-133,共4页 Electric Power Automation Equipment
关键词 RS-485总线 水轮机 温度巡检仪 温度监测 PC在线检测 RS-485 bus hydroturbine temperature inspection instrument temperature monitoring PC online test
  • 相关文献

参考文献13

二级参考文献48

  • 1唐列,王晓龙,周普会.基于objectARX的水轮机选型软件[J].水利水电科技进展,2005,25(1):53-55. 被引量:2
  • 2冯复生.国产20万kW汽轮发电机多次事故的分析及防止措施[J].电力技术(北京),1990,23(8):2-7. 被引量:9
  • 3-.能源部电力司国产200MW、300MW汽轮发电机制造质量及运行问题的调查报告[M].,1991..
  • 4中国电工技术学会.中国电机工程学会关于陡河、哈尔滨第三发电厂200MW汽轮发电机定子绕组短路等技术问题的调查报告[M].,1988..
  • 5刘大恺.水轮机[M].北京:中国水利水电出版社,1997..
  • 6史进渊.汽轮机通流部分故障诊断模型的研究[J].中国电机工程学报,1997,17(1):29-32. 被引量:27
  • 7Beguenane R, Benbouzid M E H. Induction Motors Thermal Monitoring by Means of Rotor Resistance Identification. IEEE Trans on Energy Conversion, 1999, 14(3): 566~570
  • 8Na11t Sa11d M S, Benbouzid M E H. H-G Diagram Based Rotor Parameters Identification for Induction Motors Thermal Monitoring. IEEE Trans on Energy Conversion, 2000, 15(1): 14~18
  • 9Tsai H, Demcko J, Farmer R G. On-line Synchronous Machine Parameter Estimation from Small Disturbance Operating Data. IEEE Trans on Energy Conversion, 1995, 10(1): 25~35
  • 10Verbeeck J, Pintelon R, Lataire P. Influence of Saturation on Estimated Synchronous Machine Parameters in Standstill Frequency Response Tests. IEEE Trans on Energy Conversion, 2000, 15(3): 277~283

共引文献127

同被引文献66

引证文献8

二级引证文献21

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部