摘要 鉴于目前许多工业过程所采用的 D D ZⅢ型系列仪表负载均在0~750Ω以内, 实际应用时往往受到限制, 给出了一种高负载恒流源电路的设计方法。这种高负载恒流源电路装置, 不仅具有恒流特性好, 负载电阻高的特点, 同时具有良好的实用性和通用性, The burden of DDZ Ⅲ instrument used by many industry process is within 0~750Ω.This kind of instrument is always restricted in practice.A suitable high burden constant current circuit is presented in this paper.It can solve the problem effectively.This circuit not only has a constant current performance and high burden resistance,but also has a better practicability and general usage.It has been used in a boiler water level system.
出处 《现代电力》 1999年第3期71-74,共4页 Modern Electric Power
关键词 恒流源电路装置 自动化仪表 锅炉 水位系统 constant current source installation high burden industry process instrument