摘要
点支式玻璃幕墙的玻璃面板由支承点支承, 支承点通过玻璃上的圆洞与玻璃连结, 有钢爪式等几种连接方法。面板玻璃须采用钢化玻璃,支承钢结构包括单杆式及空腹桁架等4 种。面板计算包括应力和挠度的计算。在更复杂的支承条件下, 板的弯矩与挠度可采用 S A
The designs of a plate-glass curtain wall with multiple-supports are made of the following procedures.Holes are driven into the plate-glass and then steel-hook joints are used for its connections.All plate-glass should be made of reinforced plate-glass.The supporting steel frame should include the following kinds of king-post truss and vierendeel truss type etc.The design of plate-glass should include its stress and deflection design.Under somewhat more complicated conditions,the plate-glasses bending moment and deflection could be designed with SAP procedures.