提高DSA测量精度方法的研究 被引量:6

Research on the methods to improve the measurement accuracy of DSA
暂未订购
导出
摘要 目的探讨如何提高DSA测量的精度。方法使用7根长49.8 mm、直径5 mm钢柱,等距离并排排列在检查床面上,中间的一根钢柱作为被测物放置在X线照射野的中心,其余钢柱为校准物,被测物高出校准物0、2、4、8和12 cm,分别采集图像。用上述方法分别选择床位高度0、4和8 cm,依次采集图像。在同一序列图像中,经校准后,测量被测钢柱的长度值并计算测量值精度;在不同序列图像中采用扩展校准功能,测量与校准物同一位置同一高度的被测物的长度,计算测量精度。利用SPSS 13.0统计学软件对以上结果进行分析。使用球管30°倾角测量方法,计算出被测物至床面的高度,抬高校准物达计算的高度,采集数据后,使用扩展校准功能测量被测物长度并计算测量的精。然后将校准物置于床面测量被测物长度的精度,应用SPSS 13.0统计学软件分析前后两者测量精度的高低。结果床位高度差异,被测物与校准物纵向的高度、横向间距差异,影响测量的精度,精度差异有统计学意义。其中纵向高度差异影响精度较显著。扩展校准测量的精度最高,精度高达99.80%。使用球管30°倾角测量方法与床面校准物测量方法的精度差异有统计学意义,前者测量精度明显高于后者。结论在影响测量精度的床位高度差异,被测物与校准物纵向高度、横向间距差异因素中,纵向高度差异影响较大,高度差异越小精度越高,使用球管30°倾角测量方法明显提高测量的精度。 Objective To discuss how to improve the measures accuracy of DSA.Methods ① 7 steel columns,length 49.8mm,diameter 5mm were used,equidistant to arrange in the checking bed side by side,the middle steel column to be as the measured object was put in the centre of X-ray irradiating field.The other steel columns were used as calibration.The measured object was higher than the calibration by 0cm,2cm,4cm,8cm and 12cm,respectively.The bed heights were chosen 0cm,4cm and 8cm respectively and the above-mentioned method was adopted to collect the images.Through calibrating,the length of the steel column was measured and the measurement accuracy was calculated in the same sequence images.In the different sequence images,adopted the extended calibration function to measure the measured thing which was the same position and height,and calculated the measurement accuracy.The above-mentioned results were analyzed by the SPSS13.0 statistics software.② The tube was made by 300 inclination to calculate the height from the measured object to the bed.The calibration object was lifted to the calculated height.After collecting the images,the extended calibration function was used to measure the length and the accuracy can be calculated.Then the calibration object was placed in the bed to measure the length and calculate the accuracy.The difference accuracy between the former and latter was analyzed by the SPSS13.0 statistics software.Results ①The difference of the bed height and the difference of vertical height and horizontal interval between the measured object and the calibration influenced the level of the measurement accuracy.There was significant difference among the measurement accuracy.Among them the height difference influenced the accuracy to be the most prominent.The accuracy of the extended calibration was the highest and up to 99.80%.②There was significant difference accuracy between the tube 300 inclination measurement method and the calibration object in the bed measurement method,the former was higher than the latter.Conclusion ①Among the bed height and vertical height and horizontal interval three influence factors of accuracy,the influence of vertical height is the most prominent.The smaller the high difference is,the higher the accuracy is.②The measurement accuracy is obviously improved by the tube 300 inclination measurement method.
出处 《安徽医学》 2011年第3期350-353,共4页 Anhui Medical Journal
关键词 血管造影术 数字减影 测量 精度 介入放射 Angiography Digital subtraction Measurement Accuracy Interventional radiology
  • 相关文献

参考文献8

二级参考文献52

共引文献31

同被引文献40

引证文献6

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部