期刊文献+

优化的ATP生物发光法快速检测面粉中细菌总数 被引量:9

Research on the Rapid Detection of Bacterial Count in Flour with Optimal ATP Bioluminescent Method
在线阅读 下载PDF
导出
摘要 [目的]建立一种快速检测面粉中细菌总数的方法。[方法]采用优化的ATP生物发光法检测面粉中的细菌总数,考察D-荧光素(Ln)浓度、萤火虫荧光素酶(FL)浓度、Mg2+浓度对生物发光反应的影响。[结果]Ln浓度为70 mg/L,FL浓度为50 mg/L,Mg2+浓度为0.250 0 mmol/L时,ATP生物发光法的测定结果较理想。该法最低检测细菌总数为1.0×103cfu/ml,与传统的平板计数法具有良好的相关性(P>0.05),RSD为4.0%。[结论]优化的ATP生物发光法成本低、操作简便、反应迅速、准确可靠,能快速检测出食品中的细菌总数。 [Objective] The rapid detection method of the bacterial count in flour was established.[Method] The bacterial count in flour was tested with optimal ATP bioluminescent method and the influence of the concentration of Ln,FL and Mg2+ on ATP bioluminescence response was studied.[Result] The results indicated that when the concentration of Ln was 70 mg/L;FL,50 mg/L and Mg2+,0.250 0 mmol/L,the determination result from the method was relatively perfect.The minimum of bacterial count(1.0×103 cfu/ml) could be detected with the method,which was correlated well with the method of conventional plate count(P〉0.05) and RSD was 4.0%,[Conclusion] This method was with characteristics of low cost,easy operation,fast response,accurate and reliable,which was capable for the rapid detection of bacterial count in food.
出处 《安徽农业科学》 CAS 北大核心 2011年第7期4055-4057,共3页 Journal of Anhui Agricultural Sciences
基金 湖北省教育厅项目(Q20081801) 武汉工业学院创新基金项目(08cx006)
关键词 ATP生物发光法 平板计数法 面粉 细菌总数 ATP bioluminescent method Plate count method Flour Bacterial count
  • 相关文献

参考文献12

  • 1LUO J P,LIU X H,TL~N Q. Disposable bioluminescence-based biosensor for detection of bacterial count in food [ J ]. Analytical Biochemistry,2009, 394:1 -6.
  • 2唐倩倩,叶尊忠,王剑平,盖铃,应义斌,李雁斌.ATP生物发光法在微生物检验中的应用[J].食品科学,2008,29(6):460-465. 被引量:62
  • 3HAWRONSKYJ J M, HOLAH J. ATP: a universal hygiene monitor [ J ]. Trends in Food Science & Technolo~, ,1997,8:79 - 84.
  • 4BOER E D,BEUMER R R. Methodology for detection and typing of food- borne microorganisms [ J ]. International Journal of Food Microbiology, 1999,50 : 119 - 130.
  • 5CHAMPIAT D,MATAS N,MONFORT B,FRAASS H. Applications of bio- chenfiluminescence to HACCP[ J ]. Luminescence,2001,16 : 193 - 198.
  • 6TU S I, PATIERSON D, UKNALIS J, et al. Detection of Escherichia coli 0157:H7 using immunomagnetic capture and luciferin-luciferase ATP measurement [ J ]. Food Research International ,2000,33:375 - 380.
  • 7冯敏,刘春泉,朱佳廷,罗时石,高岳.ATP生物发光技术快速测定农产品辐照灭菌效果[J].江苏农业科学,2006,34(5):147-150. 被引量:10
  • 8SUN W,KHOSRAVI F,ALBRECHTSEN H,et al. Comparison of ATP and in vivo bioluminescence for assessing the efficiency of immunomagnetic sor- bents for live Escherichia coli O157:H7 cells[J]. Journal of Applied Mi- crobiology,2002,92 : 1021 - 1027.
  • 9BROVKO L Y. Identification of microorganisms and specific detection of bacteria using bioluminescence[ C]//Bioluminescence for food and envi- ronmental microbiological safety. Bellingham, WA : SPIE,2007:43 - 52.
  • 10BElL C,BO~7~ES C D,TOSZEGHY M J K,et al. Development of a hy- giene standard for raw milk based on the lumac ATP-bioluminescence methods[J]. Int Dairy Journal,1996,6:709 -713.

二级参考文献44

共引文献70

同被引文献103

引证文献9

二级引证文献70

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部