摘要
首先检查了北京谱仪(BES)桶部簇射计数器(BSC)对γ光子电磁簇射形成的中性径迹的沉积能量和空间位置的测量值;然后,利用辐射Bhabha事例修正了BSC的沉积能量及其误差δE;利用e+e-→γγ(γ)过程确定了BSC测量中性径迹的空间位置的误差,这些研究结果可以减小用运动学拟合方法分析包含中性径迹的物理事例的系统误差,提高BES的测量精度.
The accuracy of neutral track measurement by Barrel Shower Counter (BSC)at BES is inveshgated. The photon energy in BSC is corrected using radiative Bhabhaevents and the error is determined. The error of photon position in BSC is alsodetermined using the e+ e- process. All these results can be applied to BESanalysis including neutral tracks, and the systematic error can be remarkably reducedwhen the kinematic fit is adopted.
出处
《高能物理与核物理》
SCIE
CAS
CSCD
北大核心
1999年第7期607-615,共9页
High Energy Physics and Nuclear Physics
基金
国家自然科学基金!No19290400
No19605007