摘要
指出对空调系统中的风机、水泵等的耗能应给予与制冷机组同样的重视,系统节能应整体考虑。分析了冷却塔出水温度对系统性能的影响。
Points out that the power consumption of fans and pumps should be paid as much attention as to that of refrigeration units to save energy for the system as a whole. Analyses the effects of the temperature of cooling water from the tower on the system performance and illustrates differences of power consumption between four operation modes.
出处
《暖通空调》
北大核心
1999年第6期33-34,共2页
Heating Ventilating & Air Conditioning
关键词
冷却塔
制冷机
空调系统
节能
cooling tower, chiller, air conditioning system, energy saving