期刊文献+

Bond Performance of Fiber Reinforced Polymer (FRP) Bars in Autoclaved Aerated Concrete (AAC)

Bond Performance of Fiber Reinforced Polymer (FRP) Bars in Autoclaved Aerated Concrete (AAC)
在线阅读 下载PDF
导出
摘要 This paper concerns the bond strength of FRP bars in AAC by the concentric pullout test. Specimens were subjected to compare with mild steel bars. The bond performance including the mode of failure and bond strength was investigated with varying embedment length and surface treatment. Regarding the bond performance, embedment depth has influenced on bond strength as well as the sanded surface. Carbon fiber reinforced polymer (CFRP) pronounced the most promising results with the highest bond strength attained.
出处 《Journal of Civil Engineering and Architecture》 2010年第8期37-44,共8页 土木工程与建筑(英文版)
关键词 Bond strength fiber reinforced polymer autoclaved aerated concrete 混凝土钢筋 FRP筋 AAC 债券 蒸压加气 纤维性能 碳纤维增强复合材料 聚合物
  • 相关文献

参考文献23

  • 1Y. W. Chan and S. H. Chu, 2004. Effect of silica fume on steel fiber bond characteristics in reactive powder concrete, Cem Concr Res 34 (2004) 1167-1172.
  • 2R. Tepers, Cracking of concrete cover along anchored deformed reinforcing bars, Mag. Concr. Res. 31(106) (1979) 3-12.
  • 3M. A. Erki and S. H. Rizkalla, FRP reinforcement for concrete structures, Concrete Int J 15 (1993) 48-53.
  • 4C. W. Dolan, Developments in non-metallic prestressing tendons concrete, PCI J 35(1990) 80-88.
  • 5M. Saafi and H. Toutanji, Flexural capacity of prestressed concrete beams reinforced with aramid fiber reinforced polymer (AFRP) rectangular tendons, Construction and Building Materials 12 (1998) 245-249.
  • 6J. Larralade and R. Silva-Rodriguez, Bond and slip of FRP reinforcing bars in concrete, Journal of Materials in Civil Engineering 5 (1) (1993) 30-40.
  • 7S. Daniali, Development length for fibre reinforced plastic bars: advanced composite materials, on bridges and structures, Canadian Society for Civil Engineering (1992) 179-188.
  • 8P. Ritchie, A. David, L.W. L and M. C. Guy, External reinforcement of concrete beams using fiber reinforced plastics, ACI Structural Journal 88 (4) (1991) 490-500.
  • 9E. Cosenza, G. Manfredi and R. Realfonzo, Behaviour and modeling of bond of RRP rebar to concrete, J Compos Constr 1 (2) (1987) 40-45.
  • 10K. Shelar, Manufacturing and design methodology of hybrid fiber reinforced polymer (FRP)-Autoclaved Aerated Concrete (AAC) Panels and its response under low velocity impact, M.S. thesis, CCEE Department, University of Alabama at Birmingham, 2006.