期刊文献+

保留股骨颈型全髋关节置换术早期临床疗效分析 被引量:3

Clinical effect of femoral neck preservation in total hip arthroplasty
暂未订购
导出
摘要 目的评估保留股骨颈型全髋关节置换术早期临床疗效。方法对12例(14髋)因各种原因行保留股骨颈型人工髋关节置换术患者均采用改良Moore小切口,在头下位置将股骨头截断,保留完整的股骨颈;选择合适的外杯,外翻55°装入,内杯为超高分子聚乙烯,超半径设计保持外翻45°。随访时采用Harris髋关节评分标准进行临床评价,摄X线片了解假体位置、松动情况及异位骨化。结果 1例双髋患者术中截除股骨颈过多,致双侧假体柄远端股骨劈裂骨折,夹板固定后骨折愈合。12例均获随访15~27个月,平均18.4个月。Harris评分由术前平均52分,提高到末次随访时平均91分,差异有统计学意义(P<0.05)。X线片显示髋关节位置良好,假体无松动和下沉。结论保留股骨颈型全髋关节置换术治疗中青年髋关节疾病,保留了更多宿主骨质,利于再次假体翻修,临床疗效良好。 Objective To evaluate the early clinical effect of preserving femoral neck in total hip arthroplasty.Methods Twelve patients(14 hips) were underwent total hip arthroplasty with preservation of the femoral neck.We cut off the femoral head in infra-head position with improved Moore micro-incisions to reserve intact neck of femur.The suitable size of extra cup was selected and placed at 55°eversion angle.The internal cup which was made from ultra high molecular weight polyethylene and with ultra radius design,was placed at 45°eversion angle.Clinical evaluation was done based on Harris hip score during the follow-up and the X-ray films were taken to assess position,loosening of the prosthesis and ectopic ossification.Results The bilateral distal femur prosthesis of a bilateral patient cracked owing to excessive amputation of the collum femoris and the fractures healed after symptomatic treatment.All 12 patients were followed up 15-27 months with an average of 18.4 months.The mean Harris hip score elevated from 52 before operation to 91 of the last follow-up(P0.05).The X-ray showed that the positions of artificial hip joint were good,without loosening or sinking of prosthesis.Conclusion Total hip arthroplasty with collum femoris preseving can retain more bone,be easier for revision and has an excellent outcome.
出处 《国际骨科学杂志》 2011年第2期119-120,123,共3页 International Journal of Orthopaedics
关键词 全髋关节置换 股骨颈保留 髋关节 Total hip arthroplasty Femoral neck preservation Hip joint
  • 相关文献

参考文献7

  • 1Pipino F,M,lfetta I,GrandizioMPreservation of the femoral neck in hip arthroplasty: resits of a 13 to 17-year follow-up. J (kthop Traumat, 2000; 1(1): 31-39.
  • 2Whiteside LA,White SE, Mc Carthy DS. Effect of neck resection on torsional stability of cementless total hip replacement. Am J Orthop(Belle Mead NJ), 1945; 24(10):766-770.
  • 3Josh N/R,Advani SG, Miller F, et al. Analysis of a femoral hip prosthsis designed to reduce stress shielding. J Biomech, 2000; 33(12):1655-1662.
  • 4Khanduja V, Tek V. Sett ( The effect of a neck retaining fermral implant on leg-length inequality following total hip arthroplasty: a radiological study. J Bone Joint Surg Br, 2001; 88(6):712-715.
  • 5胡懿郃,朱勇,龙文荣,李康华,廖前德,邓展生,张超.保留股骨颈全髋关节置换的早期疗效分析[J].中国修复重建外科杂志,2004,18(5):383-385. 被引量:11
  • 6高翔,徐南伟,戚有成,张煜,农鲁明,郑栋.保留股骨颈全髋关节置换术[J].中国骨与关节损伤杂志,2008,23(3):222-224. 被引量:7
  • 7崔旭,张伯勋,李静东.不同方法髋臼重建的全髋关节置换术治疗先天性髋关节发育不良[J].中国骨与关节损伤杂志,2006,21(8):602-604. 被引量:13

二级参考文献24

  • 1车彪,王凯,刘俊,覃松.髋关节骨性关节炎的临床特征与全髋置换术[J].骨与关节损伤杂志,2004,19(7):439-441. 被引量:14
  • 2崔旭,张伯勋,李静东.不同方法髋臼重建的全髋关节置换术治疗先天性髋关节发育不良[J].中国骨与关节损伤杂志,2006,21(8):602-604. 被引量:13
  • 3[1]Malchau H, Herberts P, Eisler T, et al. The Swedish total hip replacement register. J Bone Joint Surg(Am),2002;84(Suppl -2):2
  • 4[2]Wentworth SJ, Masri BA, Duncan CP, et al. Hip prosthesis of antibiotic-loaded acrylic cement for the treatment of infections following total hip arthroplasty. J Bone joint Surg(Am),2002;84(Suppl-2):123
  • 5[3]Archibeck MJ, Berger RA, Jacobs JJ, et al. Second-generation cementless total hip arthroplasty. Eight to eleven-year results. J Bone Joint Surg(Am),2001;83(11):1 666
  • 6[4]Pipino F, Molfetta L, Granditio M. Original: Preseruation of the femoral neck in hip arthroplasty: resuts of a 13 to 17-year follow-up. J Orthop Traumat,2000(1);31
  • 7[5]Kawamura H, Dunbar MJ, Murray P, et al. The porous coated anatomic total hip replacement.A ten to fourteen-year follow-up study of a cementless total hip arthroplasty. J Bone Joint Surg(Am), 2001;83(9):1 333
  • 8[8]Tobin WJ.The internal architecture of the femur and its clinical significance. J Bone Joint Surg(Am),1995;37:57
  • 9[9]Devane Lombardi.Correlation between Prosthetic Offset and polyethylene Wear in Total Hip Arthroplasty.67th Annual Meeting Proceedings AAOS, marth 2000,Orlando,S,552-553
  • 10[10]Whiteside LA, White SE, McCarthy DS. Effect of neck resection on torsional stability of cementless total hip replacement. Am J Orthop, 1995;24(10):766

共引文献26

同被引文献21

引证文献3

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部