提出一种采用改变参考电压来校正热电偶非线性的简单方法.详细介绍了计算公式,给出了具体举例及实际误差.
The simple method by changing reference voltage for non-linear correction of thermocouples is introduced. The calculation formula is described in detail and concrete example and practical error are given.