摘要 目的:建立大体积直接进样-免试剂离子色谱法测定瓶装水中的溴酸盐和溴化物的方法。方法:选用IonpacAS19阴离子分析柱,在线产生10 mmol/L^35 mmol/L KOH为淋洗液,大体积直接进样,流速1.0 ml/min,电导检测器检测。结果:溴酸盐和溴化物在0 mg/L^0.10 mg/L范围内线性良好,精密度高(RSD%<3.0),溴酸盐相关系数0.9996,回收率在97.0%~104.5%之间,最低检出限为0.78μg/L;溴化物相关系数0.9992,回收率在92.0%~105.5%之间,最低检出限为0.25μg/L。结论:方法灵敏、快速、简单,可适用于瓶装水中溴酸盐和溴化物含量的检测。 Objective:To develop a method for determination of bromate and bromide in bottled drinking water by free reagent ion chromatography with Large volume injection.Methods: The method was based on large volume injection and IC separation under the condition of gradient eluent with 10 mmol/L^35 mmol/L KOH generation on line and flow rate of 1.0 ml/min by using the IonPac AS19 analytical column and suppressed condutivity detector.Results:This method had good linear relatity in the range of 0 mg/L^0.10 mg/L and good analytic precision(RSD%3.0).The correlation coefficient was 0.9996 for bromate and 0.9992 for bromide.The recovery rate was 97.0%~104.5% for bromate and 92.0%~105.5% for bromide.The detection limit was 0.78 μg/L for bromate and 0.25 μg/L for bromide.Conclusion: This method is sensitive,rapid and simple.It is available to determine the bromate and bromide in bottled drinking water by free reagent ion chromatography.
作者 刘丽菁 杨艳
出处 《中国卫生检验杂志》 CAS 2011年第2期358-360,共3页 Chinese Journal of Health Laboratory Technology
关键词 溴酸盐 溴化物 离子色谱 瓶装水 大体积进样 Bromate Bromide Ion chromatography Bottled drinking water Large volume injection
  • 相关文献

参考文献7

二级参考文献29

共引文献98

同被引文献25

  • 1黄丽,郑惠华.离子色谱法测定矿泉水中溴酸盐[J].中国卫生检验杂志,2005,15(3):327-327. 被引量:12
  • 2陆幽芳,宋伟,张立辉,马永建,陈守建.离子色谱法测定饮用水中痕量溴酸盐[J].中国卫生检验杂志,2005,15(11):1298-1300. 被引量:7
  • 3应波,李淑敏,岳银玲,鄂学礼.抑制型电导检测离子色谱法测定饮用水中的痕量溴酸盐[J].色谱,2006,24(3):302-304. 被引量:23
  • 4岳银玲,李淑敏,应波,鄂学礼.超市中瓶装矿泉水溴酸盐含量的调查[J].中国卫生检验杂志,2006,16(6):677-678. 被引量:25
  • 5GB19298-2003 瓶(桶)装饮用水卫生标准[S].2003.
  • 6GB5750-2006,生活饮用水标准检验方法[S].
  • 7Richardson S D. Disinfection by - products and other e-merging contaminants in drinking water [ J ]. Trends in Analytical Chemistry, Vol. 2003 ,22( 10) :666 -684.
  • 8Binghui Z,Zhixiong Z, Jing Y. Ion chromatographic de-tennination of trace iodate,chlorite,chlorate,bromide, bromate and nitrite in drinking water using suppressed conductivity detection and visible detection [ J ] . Journal of Chromatography,2006,1118(1): 106 - 110.
  • 9Fotsing M,Borbeau B,Prevost M. Low - level bromate a-nalysis in drinking water by ion chromatography with optimized suppressed conductivity cell current followed by a post - column reaction and UV/Vis detection [ J ] . J Environ Sci Health A Tox Hazard Subst Environ Eng ,2011,46(4):420-425.
  • 10Ufermanna P,Petersena H,Exnerb M. Disinfection aboard cruise liners and naval units : Formation of disinfection by -products using chlorine dioxide in ifferent qualities of drinking water [ J ]. International Journal of Hygiene and Environmental Health,2011,215 :86 -90.