期刊文献+

螺旋CT动脉造影在糖尿病下肢动脉闭塞性病变中的应用 被引量:10

The clinical application of spiral CT (SCT) angiography in diagnosis of diabetic lower limb arterial occlusive disease
原文传递
导出
摘要 目的探讨螺旋CT动脉造影(CTA)在糖尿病下肢动脉闭塞性病变中的诊断价值及临床意义。方法对27例糖尿病伴下肢不适的患者行CTA检查,范围腹主动脉远段至足底,层厚5 mm,螺距1.375,重建层厚1.25 mm,重叠50%,对比剂量100~150 ml,注射速率3.5 ml/s,对全部图像行最大密度投影(MIP)、容积再现(VR)和多平面重组(MPR)后处理并进行评价。结果所有病例血管重建图像显示良好,病变血管表现为管腔不规则、单发或多发狭窄或闭塞、局部侧支血管形成、部分管壁钙化等。结论 CTA可准确地显示糖尿病血管病变情况,有效地指导临床治疗,有显著的临床应用价值。 Objective To evaluate the diagnostic value of SCT angiography for lower limb artery occlusive disease. Methods 27 cases clinlcally suspected as diabetic arterial occlusive disease of lower extremity received SCT angiography. Results In 27 cases the lower limb arterial occlusive lesions were successfully demonstrated. The pathological changes in SCT included irregularity of vascular lumen,single and/or multiple stenosis and occlusion, collateralization and calcification. Conclusion Spiral (2T is valuable for demonstrating diabetic arterial occlusive lesion in lower extremity.
出处 《中国糖尿病杂志》 CAS CSCD 北大核心 2011年第2期116-118,共3页 Chinese Journal of Diabetes
关键词 糖尿病 下肢动脉 电子计算机断层扫描 血管造影术 Diabetes Artery of lower extremity Computer tomography Angiography
  • 相关文献

参考文献8

二级参考文献55

  • 1陈清棠 主编.临床神经病学[M].北京:北京科学技术出版社,2002.178.
  • 2[1]Ota H, Takase K, Igarashi K, et al. MDCT compared with digital subtraction angiography for assessment of lower extremity arterial occlusive disease: importance of reviewing cross-sectional images[J]. AJR, 2004, 182(1) :201-209.
  • 3[3]Willmann JK, Mayer D, Banyai M, et al. Evaluation of peripheral arterial bypass grafts with multi-detector row CT angiography:comparison with duplex US and digital subtraction angiography[J]. Radiology, 2003,229(2) :465-474.
  • 4[5]Katz DS, Hon M. CT angiography of the lower extremities and aortoiliac system with a multi-detector row helical CT scanner:promise of new opportunities fulfilled [J]. Radiology, 2001, 221(1) :7-10.
  • 5[6]Rubin GD, Schmidt AJ, Logan LJ, et al. Multi-detector row CT angiography of lower extremity arterial inflow and runoff: initial experience[J]. Radiology, 2001,221(1): 146-158.
  • 6[7]Klingenbeck-Regn K, Schaller S, Flohr T, et al. Subsecond multislice computed tomography: basics and applications[J]. Eur J Radiol, 1999,31(2) :110-124.
  • 7吴阶平 裘法祖.黄家驷外科学[M](第五版)[M].北京:人民卫生出版社,1996.923.
  • 8Berland LL, Smith JK. Multidetector - array CT:once again, technology creates new opportunities[J]. Radiology, 1998 , 209(2):327 - 329.
  • 9Hu H, He HD, Foley WD, et a. Four mulitidetector- row helical CT:image quality and volume coverage speed[J]. Radiology,2000, 215(2):55-62.
  • 10Kalender WA. Thin- section three- dimensional spiral CT: is isotropicimaging possible [J]. Radiology, 1995, 197(3) :578 - 580.