摘要
介绍光电式电流互感器(POSS-OTA)挂网运行计量稳定性的测试方法,阐述了光电式电流互感器挂网运行测量精度的理论分析和实测数据分析,以及光电式电流互感器挂网运行计量稳定性的评价结论。
Power Optical Sensor Solution-Optical Current Transducer(POSS-OCT) has tentatively operated in transmission network.This paper aims to introduce the testing method of its measurement stability.The measurement accuracy is expounded in theory and analyzed in the light of actual data.Finally,the paper draws the evaluation conclusion of the Measurement Stability.
出处
《华东电力》
北大核心
2011年第1期100-103,共4页
East China Electric Power
关键词
光电式电流互感器
挂网运行
计量稳定性
测试
Power Optical Sensor Solution-Optical Current Transducer
tentative operation
measurement stability