摘要
详述在福建地区首次采用飞灰底饲回燃技术改造一台10t/h地鼓泡流化床锅炉的情况。技改后的测试结果表明,底饲过程安全可靠,技改效果非常明显,锅炉出力超出原设计值44%,锅炉效率也提高了10%以上。
A 10t/h BFB boiler retrofitted by applying fly ash underfeed recycling technology for the first time in Fujian area is described in detail in this paper. The experimental results indicate that underfeed is safe and reliable. Boiler output is raised to 44% over designed value, and boiler efficiency is also increased more than 1o%.
出处
《锅炉技术》
北大核心
1999年第8期29-32,共4页
Boiler Technology
关键词
硫化床锅炉
飞灰低饲回燃
无烟煤
Fluidized bed boiler Fly ash underfeed recycling Anthracite