摘要
对辐射致色薄膜剂量计(PVG膜剂量计)的辐照响应过程进行了研究,计算出了PVG膜剂量计中孔雀绿(MG+)的辐射化学产额G(MG+).当膜中组分隐色孔雀绿(LMG)的量含量为80μmol·g(-1),有机卤代物(RX)与LMG的质量比为0.5时,其G值为0.236μmol·J(-1).考查了膜中组分LMG和RX的量含量变化对G(MG+)的影响.表明PVG膜剂量计中由于LMG和RX的量含量波动而引进的偏差在1%以下,并不妨碍其作为常规剂量计的使用.
The irradiation response of radiochromic film dosimeter(PVG) is investigated,and the radintion chemical yields of malachite green(MG+) in PVG film dosimerter are given. The G value of MG+ is 0.236μmol. J-1 in the content of leuco malachite green(LMG) 80 μmol. g-1 and at the mass ratio of halogenatal organic compound(RX) to LMG 0.5. The influences of the content of LMG and RX on G(MG+) are studied. The deviation of PVG film dosimeter resulted from the content variation of LMG and RX is much less than 1%, which doesn't hamper the use of PVG as a routine dosimeter.
出处
《北京师范大学学报(自然科学版)》
CAS
CSCD
北大核心
1999年第2期238-241,共4页
Journal of Beijing Normal University(Natural Science)
基金
国际原子能机构8580/RB合同资助
关键词
辐射化学
剂量计
辐照响应
组分含量
偏差
radiochromic film dosimeter
radiation chemical yield
malachite green
leuco malachite green
leuco malachite green