摘要
针对某厂3号炉低负荷燃烧不良的问题,通过实际的运行经验和低负荷燃烧时总结出来的方法,从校验氧量测点、提高煤粉浓度、改进配风方式等方面提出相应的措施。
As for this question of the poor stable combustion at low load for No. 3 boiler in a electric power, based on practical operating experiences and methods of combustion at low load, this paper proposes the corresponding measures from examining measuring point of oxygen quantity, improvement of the coal concentration, the air distribution mode and so on.
出处
《贵州电力技术》
2010年第12期78-79,共2页
Guizhou Electric Power Technology
关键词
锅炉
低负荷稳燃
安全
氧量
煤粉浓度
boiler
stable combustion at low load
safety
oxygen quantity
coal concentration