期刊文献+

地下工程钢纤维膨胀混凝土试验研究 被引量:2

Test research of steel fiber reinforced expansion agent concrete in underground project
在线阅读 下载PDF
导出
摘要 为解决目前东部沿海地区地下防护工程结构强度与抗侵彻能力低、易开裂、易渗漏等问题,选取普通混凝土、单掺钢纤维混凝土、单掺膨胀剂混凝土和钢纤维与膨胀剂双掺的钢纤维膨胀混凝土4种类型进行对比试验研究。结果显示:与普通混凝土、单掺钢纤维混凝土和单掺膨胀剂混凝土相比较,经优化后的钢纤维膨胀混凝土泵送性能优良,抗压、抗弯、抗劈拉强度及抗裂、抗渗性能有了显著地提高,是一种适于地下防护工程结构自防水的高性能混凝土。 The underground shelter projects which locate at the eastern region of china along the seaboard are the important targets to be attacked.In order to solve the problems of frequent fracturing,cracking,leaking and so on.This paper chooses four kinds of different types of concretes which are conventional concrete(C),steel fiber reinforced concrete(SFRC),expansion agent concrete(EC) and steel fiber reinforced expansion agent concrete(SFREC) to research their performances.The test results show that SFREC with the optimal mix proportion has good pumpability.When compared with C,SFRC and EC,SFREC will produce remarkable enhancement in the compressive strength,bending strength,especially in the splitting strength and the ability of anti-shrinking,anti-cracking and anti-penetration.It is testified that SFREC which adapt to the underground shelter projects is a kind of high performance concrete and self-water proofing concrete.
作者 罗成立
出处 《混凝土》 CAS CSCD 北大核心 2010年第12期76-77,110,共3页 Concrete
关键词 地下工程 混凝土 钢纤维 膨胀剂 underground project concrete steel fiber expansion agent
  • 相关文献

参考文献8

  • 1吴中伟.纤维增强-水泥基材料的未米[C]//纤维水泥制品行业论文选集(1965-1999).北京:中国建材工业出版社,2000.
  • 2GB/T50080-2002.普通混凝土拌合物性能试验方法标准[S].[S].,..
  • 3CECS13:89.钢纤维混凝土试验方法[S].[S].,..
  • 4沈荣熹,王璋水,崔玉忠.纤维增强水泥与纤维增强混凝土[M].北京:化学工业出版社,2006.
  • 5蒋金洋,孙伟,张云升,金祖权,洪锦祥,王晶.索塔锚固区泵送高性能钢纤维混凝土的研制[J].工业建筑,2007,37(1):77-81. 被引量:1
  • 6SOROUSHIAN P,RAVANBAKHSH S.Control of plastic shrinkage cracking with specialty cellulose fibers[J].ACI Materials Journal,1998,95(7-8):429-435.
  • 7CECS 38:2004,混凝土结构耐久性设计与施工指南[S].
  • 8ASTM C 1202-05,Standard test method for electrical indication of concrete's ability to resist chloride Ion penetration[S].

二级参考文献7

  • 1何永佳,胡曙光,马保国,吕林女,丁庆军.免振捣泵送混凝土的工作性评价[J].桂林工学院学报,2005,25(1):50-53. 被引量:12
  • 2赵国潘 彭少民.钢纤维混凝土结构[M].中国建筑工业出版社,1999..
  • 3ACI 305 Hot Weather Concreting
  • 4Singh S P,Singh B,Kaushik S K.Probability of Fatigue Failure of Steel Fibrous Concrete.Magazine of Concrete Research,2005,57(2):65 -72
  • 5Lee M K,Barr B I G.An Overview of the Fatigue Behaviour of Plain and Fibre Reinforced Concrete.Cement & Concrete Composites,2004,26(4):299-305
  • 6Shan Surendra P,Weiss W Jason,Wei Yang.Shrinkage Cracking Can it be Prevented.Concrete International,1998(4):52-56
  • 7中国工程院土木水利与建筑学部,工程结构安全性与耐久性研究咨询项目组.混凝土结构耐久性设计与施工指南.北京:中国建筑工业出版社,2004.31-36