期刊文献+

光学相干层析术无损检测血糖的测量效果评价 被引量:2

Evaluation of non-invasive detection of blood glucose using OCT
在线阅读 下载PDF
导出
摘要 为改进现有光学相干层析术(OCT)无损检测血糖评价方法的不足,提出将OCT信号斜率相对变化量和相对标准误差相结合来评价测量结果,并同时得到血糖的理论测量精度。首先,分析了OCT系统共焦函数对测量结果的影响及OCT信号斜率相对误差的计算方法,然后,通过对3只新西兰白兔进行活体实验来评价OCT无损检测血糖的测量结果。在测量血糖引起的OCT信号斜率相对变化量的同时,对OCT信号斜率相对误差也进行了计算,从而获得血糖的理论测量精度。新西兰白兔活体实验表明,线性度较好的拟合区间下OCT信号斜率相对变化量和相对误差分别为(3.7%)/mmol和0.068,(3.4%)/mmol和0.026,(0.93%)/mmol和0.019,血糖理论测量精度分别为±3.7 mmol,±1.5 mmol和±4.1 mmol。OCT信号斜率的相对变化量和相对标准误差相结合的评价方法能更有效地提高血糖理论测量精度,而且拟合区间越大,血糖的测量精度越高。 To improve the evaluation method of non-invasive detection of blood glucose by Optical Coherence Tomography(OCT),a method combining the relative variance of OCT signal slope with the relative standard error was presented to evaluate the measurement effect and to obtain the theoretical precision of blood glucose detection.Firstly,the effect of the OCT confocal function on the blood glucose detection and the computing method of the relative error of OCT signal slope were given.Then,the relative variance and standard error of the OCT signal slope via a vivo experiment on 3 New Zealand rabbits were carried out to evaluate the non-invasive detection of blood glucose.Obtained results indicate that the relative variance and standard error of OCT signal slope are(3.7 %)/mmol 0.068,(3.4 %)/mmol 0.026,(0.93 %)/mmol 0.019,respectively,and the theoretical measuring precision of blood glucose detection are ±3.7 mmol,±1.5 mmol and ±4.1 mmol,respectively.It concludes that the the evaluation method of combining the relative variance and standard error of OCT signal slope can greatly improve the theoretical measuring precision of blood glucose detection,and the larger the fitting interval is,the higher the measuring precision is.
出处 《光学精密工程》 EI CAS CSCD 北大核心 2010年第12期2688-2694,共7页 Optics and Precision Engineering
基金 广东省科技计划资助项目(No.2008B030303055)
关键词 光学相干层析术 无损检测 血糖 测量精度 评价方法 Optical Coherence Tomography(OCT) non-invasive detection blood glucose measurement precision evaluation method
  • 相关文献

参考文献4

二级参考文献37

  • 1张泰石,李刚,郑羽,林凌,刘晶晶.用线性补偿算法和CCD响应补偿来提高频谱OCT图像质量[J].光学精密工程,2006,14(5):929-933. 被引量:7
  • 2郑羽,李刚,张泰石,刘晶晶,林凌.采用特殊镀膜分束器的OCT系统性能分析[J].光学精密工程,2006,14(6):1082-1087. 被引量:2
  • 3FERCHER A F,HITZENBERGER C K.Measurement of intraocular distances by backscattering spectral interferometry[J].Journal of Optics Communications,1995,5:43-48.
  • 4FERCHER A F,DREXLER W,HITZENBERGER C K,et al.Optical coherence tomography-principles and applications[J].Reports on Progress in Physics,2003,66:239-303.
  • 5TOMLINS P H,WANG R K.Theory,developments and applications of optical coherence tomography[J].Journal of Physics D-Applied Physics,2005,38(15):2519-2535.
  • 6MANABU S,ICHIRO W.Fundamental characteristics of a synthesized light source fro optical coherence tomography[J].Journal of Applied Optics,2005,44(13):2471-2481.
  • 7FROSZ M H,JUHL M,LANG M H.Optical coherence tomography system design and noise analysis[R].Roskilde,Denmark:Ris National Laboratory,2001.
  • 8WU K J,LI G.Effective detecting depth of OCT system in single layer scattering tissue[J].Journal of Tianjin University,2005,38(8):706-710.
  • 9WOJTKOWSKI M,LEITGEB R,KOWALCZYK A,et al.In vivo human retinal imaging by Fourier domain optical coherence tomography[J].Journal of Biomedical Optics,2002,7(3):457-463.
  • 10LEITGEB R,HITZENBERGER C K,FERCHER A F.Performance of Fourier domain vs.time domain optical coherence tomography[J].J.Opt.Exp.,2003,11(8):889-894.

共引文献2

同被引文献6

引证文献2

二级引证文献6

相关作者