摘要
介绍了分点进水多级A/O污水处理工艺主要设计参数的理论推导和选取方法,通过实际工程设计,分别对多级A/O工艺的反应器级数、反应器流量比例系数(Ri=Qi/Q)、反应器缺氧区和好氧区容积等进行了详细计算,并与单级A/O工艺进行了比较。分点进水多级A/O工艺具有系统污泥浓度高、硝酸盐浓度低、BOD5浓度均衡、节省反应池容积、无需内回流装置等优点。
This paper introduced the theoretical derivation and application of the main design parameters for step feed multi-grade A/O wastewater treatment process. Through the practical engineering design, the grade number of multi-grade A/O reactors, reactor flow rate proportionality coefficient (Ri =Qi/Q), and reactor (A/O) volume calculation were carried out in details. Compared with single-grade A/O process, the step feed multi-grade A/O process has the advantages of high system sludge concentration, low nitrate concentration, balanced BODs concentration, reaction tank volume saving, and no need of internal reflux unit, and so on.
出处
《给水排水》
CSCD
北大核心
2011年第1期9-13,共5页
Water & Wastewater Engineering
关键词
污水处理厂
多级A/O工艺
分点进水
设计计算
反硝化速率
Wastewater treatment plant
Multi-grade A/O process
Step feed
Design calculation
Denitrification rate