期刊文献+

一种新型植骨重建钛网的三维有限元研究 被引量:5

Three-dimensional finite elements study of a new titanium mesh cage for bone grafting
暂未订购
导出
摘要 目的研究新型植骨重建钛网的生物力学特点及其避免术后沉陷的有效性。方法设计并研制了一种新型的植骨重建钛网,以现有钛网为研究对照,建立使用2种钛网的椎体次全切除植骨重建手术的三维有限元模型,施加载荷,模拟术后颈椎活动,分别在屈曲、侧屈及扭转3种工况下施加73.6N的预载荷,观察钛网、钢板以及相邻椎体终板的应力分布。结果在3种不同工况条件下,使用新型植骨重建钛网较使用现有钛网可使钢板承受应力减低1.48~3.95MPa(23.5%~41.3%),钛网承受应力增加0.61~1.13MPa(12.2%~22.2%),相邻椎体下终板承受应力降低0.41~1.43MPa(27.7%~44.9%),相邻椎体上终板承受应力降低0.91~1.42MPa(28.0%~38.6%)。结论颈前路椎体次全切除减压术中使用新型钛网进行植骨重建可一定程度上增加手术节段稳定性,降低术后钛网沉陷的可能性。 Objective To study the biomechanical features of a new type titanium mesh cage and its effectiveness in avoiding postoperative subsidence. Methods A new type titanium mesh cage was designed. Two three-dimensional finite element models of anterior cervical eorpectomy and fusion with new type titanium mesh cage or current type titanium mesh cage were established. The models were tested under preliminary loading of 73.6 N to simulate cervical physical action including flexion, lateral bending and rotation. The stress distribution of titanium mesh cage, cervical plate and adjacent vertebral end- plates were compared between 2 models. Results Under 3 preliminary loading, comparing with current type titanium mesh cage, the new type titanium mesh cage made the stress distribution of cervical plate decreased by 1.48 - 3.95 MPa (23.5% - 41.3% ), and the stress distribution of TMC increased by 0.61 - 1.13 MPa ( 12.2% - 22.2% ), and the stress distribution of the adjacent upper vertebral endplate decreased by 0.41 - 1.43 MPa (27.7 % -44.9% ), and the stress distribution of the adjacent below vertebra[ endplate decreased by 0.91 - 1.42 MPa (28.0% - 38.6% ). Conclusion Anterior cervical corpectomy and fusion with new type titanium mesh cage will be helpful for increasing the segment stability and decreasing the possibility of postoperative titanium mesh cage subsidence.
出处 《脊柱外科杂志》 2010年第5期290-294,共5页 Journal of Spinal Surgery
基金 上海市科委基金资助(074119629)
关键词 颈椎 截骨术 骨移植 外科网 设备失败 有限元分析 Cervical vertebrae Osteotomy Bone transplantation Surgical mesh Equipment failure Finite element analysis
  • 相关文献

参考文献21

  • 1Majd ME,Vadhva M,Holt RT.Anterior cervical reconstruction using titanium cages with anterior plating[J].Spine (Phila Pa 1976),1999,24(15):1604-1610.
  • 2Eck KR,Bridwell KH,Ungacta FF,et al.Analysis of titanium mesh cages in adults with minimum two year follow up[J].Spine (Phila Pa 1976),2000,25(18):2407-2415.
  • 3Riew KD,Rhee JM.The use of titanium mesh cages in the cervical spine[J].Clin Orthop Relat Res,2002,(394):47-54.
  • 4Chuang HC,Cho DY,Chang CS,et al.Efficacy and safety of the use of titanium mesh cages and anterior cervical plates for interbody fusion after anterior cervical corpectomy[J].Surg Neurol,2006,65(5):464-471.
  • 5Hasegawa K,Abe M,Washio T,et al.An experimental study on the interface strength between titanium mesh cage and vertebra in reference to vertebral bone mineral density[J].Spine (Phila Pa 1976),2001,26(8):957-963.
  • 6Dorai Z,Morgan H,Coimbra C.Titanium cage reconstruction after cervical corpectomy[J].J Neurosurg,2003,99(1 Suppl):3-7.
  • 7Narotam PK,Pauley SM,McGinn GJ.Titanium mesh cages for cervical spine stabilization after corpectomy:a clinical and radiological study[J].J Neurosurg,2003,99(2 Suppl):172-180.
  • 8Hee HT,Majd ME,Holt RT,et al.Complications of multilevel cervical corpectomies and reconstruction with titanium cages and anterior plating[J].J Spinal Disord Tech,2003,16(1):1-9.
  • 9郭永飞,陈德玉,王良意,徐建伟,王新伟.颈椎椎体终板倾斜角的影像学测量[J].中国临床康复,2003,7(14):2006-2007. 被引量:16
  • 10Akamaru T,Kawahara N,Sakamoto J,et al.The transmission of stress to grafted bone inside a titanium mesh cage used in anterior column reconstruction after total spondylectomy:a finite-element analysis[J].Spine (Phila Pa 1976),2005,30(24):2783-2787.

二级参考文献20

  • 1徐建伟,陈德玉,贾连顺.颈前路椎体次全切钛网植骨钛网裁切技术探讨[J].脊柱外科杂志,2003,1(5):257-259. 被引量:9
  • 2薛庆云,黄公怡.颈椎退变的X线分析[J].中华骨科杂志,1994,14(9):530-533. 被引量:30
  • 3Mirovsky Y ,Neuwirth MG.Comparison between the outer table and intracortical methods of obtaining autogenous bone graft from the iliac crest[J].Spine,2000,25(13): 1722-1725.
  • 4Fowler BL,Dall BE, Rowe DE. Complications associated with harvesting auto- genous iliac bone graft[J].Am J Orthop, 1995,24(12) :895-903.
  • 5Banwart JC, Asher MA, Hassanein RS. Iliac crest bone graft harvest doner site morbidity[J].Spine,1995,20(9):1055-1060.
  • 6Riew KD, Rhee JM. The use of titanium mesh cages in the cervical spine [J].Clin Orthop,2002,394:47-54.
  • 7John ST,Chen XS,James M,et al. Single stage anterior cervical reconstruction with titanium mesh cages,local bone graft,and anterior plating[J].The Spine Journal,2003(3):294-300.
  • 8Kanayama M, Hashimoto T,Shigenobu K,et al. Pitfalls of anterior cervical fusion using titanium mesh and local autograft[J].J Spinal Disord Tech,2003,16(6):513-518.
  • 9Hasegawa K,Abe M,Washio T,et al.An experimental study on the interface strength between titanium mesh cage and vertebra in reference to vertebral bone mineral density [J].Spine ,2001,26(8) :957-963.
  • 10Truumees E, Demetropoulos CK,Yang KH,et al. Effects of disc height and distractive forces on graft compression in an anterior cervical discectomy model [J].Spine,2002,27 (22):2441-2445.

共引文献77

同被引文献77

  • 1郭永飞,陈德玉,徐建伟,王新伟,王良意,何志敏,陈宇,袁文,贾连顺.颈前路钛网植骨融合术后钛网沉陷的原因分析[J].中国脊柱脊髓杂志,2005,15(7):409-413. 被引量:42
  • 2罗家明,吴小涛,何海军.颈前路多节段椎体次全切除钛笼植入重建颈椎生理弧度的实验研究[J].东南大学学报(医学版),2006,25(3):200-204. 被引量:6
  • 3郭永飞,陈德玉,陈宇,何志敏,刘军海,王新伟,袁文,贾连顺.颈前路术后钛网下沉对颈椎曲度和手术疗效的影响[J].中国骨与关节损伤杂志,2006,21(9):681-683. 被引量:14
  • 4王文军,汪向东,朱一平,羊明智,王麓山,姚女兆,晏怡果.新型翼形钛网在颈椎病手术治疗中的初步临床应用[J].中国矫形外科杂志,2007,15(15):1126-1128. 被引量:3
  • 5Erfanian P,Tenzif S,Guerriero RC. Assessing effects of a semicustomized experimental cervical pil ow on symptomatic adults with chronic neck pain with and without headache[J].J Can Chiropr Assoc,2004,(01):20-28.
  • 6Hagino C,Boscariol J,Dover L. Before/after study to determine the effectiveness of the align right cylind rical cervical pil ow in reducing chronic neck pain severity[J].Journal of Manipulative and Physiological Therapeutics,1998,(02):89-93.
  • 7Wil inger M,Ko CW,Hoffman HJ. Factors Associated With Caregiver’s Choice of Infant Sleep Position,1994-1998[J].Journal of the American Medical Association,2000,(16):2135-2142.
  • 8Montgometry-Downs HE,O’Brien LM,Gul iver TE. Polysomnographic Characteristics in Normal Preschool and Early School-Aged Children[J].Pediatrics,2006.741-753.
  • 9Tan J,LI L,Sun G. C1 lateral mass-C2 pedicle screws and crosslink compression fixation for unstable atlas fracture[J].Spine (Phila Pa 1976),2009,(23):2505-2509.
  • 10Taylor WR,Roland E,Ploeg H. Determination of orthotropic bone elastic constants using FEA and modal anslysis[J].Journal of Biomechanics,2002,(06):767-773.

引证文献5

二级引证文献25

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部