研制了中性载体三辛胺PVC膜pH电极,其响应的pH线性范围为2.5~12.3,斜率53.6mV/pH,并用于水样和含F离子水样pH测定。
Triocylamine is used as a neutral carrier for preparing PVC membrane pH electrodes.Linear pH range of the electrode equal to 2.5~12.3,while its slope is 53.6 mV/pH(20 ℃).The elctrode is successfully applied to measuring the pH of water samples.