期刊文献+

冠状动脉管壁高分辨力磁共振成像的初步研究 被引量:1

Initial study of high-resolution magnetic resonance imaging for coronary artery wall
暂未订购
导出
摘要 目的:探讨冠状动脉管壁的高分辨MR成像方法,评价其在显示冠状动脉细微解剖结构方面的应用价值。方法:选取20例健康志愿者在1.5T MR设备上行高分辨冠状动脉管壁断面成像,由两位高年资MRI医师对图像质量进行评分,并在评分较高的图像上测量血管内径及管壁厚度等数据。结果:18例志愿者均完成检查,共获得冠状动脉管壁横轴面图像97帧,其中右冠状动脉(RCA)59帧,平均得分2.15分;左冠状动脉(LCA)38帧,平均得分1.39分,RCA图像质量优于LCA。在RCA图像中质量评分≥2分的图像上测量血管内径及管壁厚度,RCA近段内径平均值为(3.55±0.51)mm,管壁厚度平均值为(1.11±0.23)mm。结论:冠状动脉管壁MR高分辨成像可以显示冠状动脉管壁细微解剖结构,并可定量测量和分析相关数据,在冠状动脉疾病的临床诊断及研究中具有较大的应用前景。 Objective:To study the technique of high resolution MR imaging of coronary artery (CA) wall,and to assess its value in demonstrating anatomic structure of CA wall in detail. Methods: 20 healthy volunteers were selected to un dergo high resolution MR imaging of CA with a 1.5T MR system. All of the images obtained were scored by two senior ra diologists in MRI major. The intra-luminal diameter of CA and the thickness of the wall were measured on cross section images with higher scores. Results: 18 volunteers had the study successfully completed and 97 cross section images of CA were obtained. Of all the images,59 were of right CA with the mean score as 2.15 and 38 were of left CA with the mean score as 1.39. The image quality of RCA was better than that of LCA. Measurement was performed on the cross section images of RCA with scores ≥2. The mean intra-luminal diameter of RCA was (3.55±0.51)mm and the mean wall thickness was (1.11±0.23)mm. Conclusion: The detailed anatomy structure and quantitative measurement of CA could be demonstrated on the high-resolution MR imaging, the data acquired could he used in clinical practice and research for CA disorders with good prospects.
出处 《放射学实践》 北大核心 2010年第11期1241-1244,共4页 Radiologic Practice
关键词 冠状动脉 磁共振成像 高分辨力 血管造影术 Coronary artery Magnetic resonance imaging High resolution Angiography
  • 相关文献

参考文献9

  • 1Little WC,Constantinescu M,Applegate RJ,et al.Can coronary angiography predict the site of a subsequent myocardial infarction in patients with mild-to-moderate coronary artery disease[J].Circulation,1988,78(5 Pt 1):1157-1166.
  • 2Yuan C,Mitsumori LM,Ferguson MS,et al.In vivo accuracy of multispectral magnetic resonance imaging for identifying lipid-rich necrotic cores and intraplaque hemorrhage in advanced human carotid plaques[J].Circulation,2001,104(17):2051-2056.
  • 3Hoffman MB,Wickline SA,Lorenz CH.Qualification of in plane motion of the coronary arteries during the cardiac cycle:implications for acquisition window duration for MR flow qualification[J].J Magn Reson Imaging,1998,8(3):568-576.
  • 4Fayad ZA,Fuster V,Fallon JT,et al.Noninvasive in vivo human coronary artery lumen and wall imaging using black-blood mag-netic resonance imaging[J].Circulation,2000,102(5):506-510.
  • 5Botnar RM,Kim WY,Bernert P,et al.3D coronary vessel wall imaging utilizing a local inversion technique with spiral image acquisition[J].Magn Reson Med,2001,46(5):848-854.
  • 6Botnar RM,Stuber M,Kissinger KV,et al.Noninvasive coronary vessel wall and plaque imaging with magnetic resonance imaging[J].Circulation,2000,102(21)..2582-2587.
  • 7Ioannis Koktzoglou,Orlando Simonetti,Debiao Li.Coronary artery wall imaging:initial experience at 3 tesla[J].J Magn Reson imaging,2005,21(2):128-132,.
  • 8Jaeseok Park,Andrew C.Larson,Qiang Zhang,et al.High-resolution steady-state free precession coronary magnetic resonance angiography within a breath-hold:parallel imaging with extended cardiac data acquisition[J].Magn Reson Med,2005,54(5):1100-1106.
  • 9Spuentrup E,Katoh M,Stuber M,et al.Coronary MR imaging Using free-breathing 3D steady-state free p recession with radial k-space sampling[J].Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr,2003,175(10):1330-1334.

同被引文献16

  • 1程流泉,高元桂,盛复庚,蔡幼铨.磁共振心脏成像平面的定位与解剖[J].中国医学影像学杂志,2004,12(5):321-324. 被引量:11
  • 2Desai MY, Lai SG, Barmet C, et al. Reproducibility of 3D free-breathing magnetic resonance coronary vessel wall ima- ging [J]. Eur Heart J, 2005, 26(21):2320-2324.
  • 3Scott AD, Keegan J, Mohiaddin RH, et al. Noninvasive de- tection of coronary artery wall thickening with age in healthy subjects using high resolution MRI with beat-to-beat respirato- ry motion correction [J]. J Magn Reson Imaging, 2011, 34 (4) :824-830.
  • 4Lin K, Bi X, Taimen K, et al. Coronary wall MR imaging in patients with rapid heart rates : a feasibility study of black- blood stead'y-state free precession (SSFP) [J]. Int J Card- iovasc Imaging, 2012, 28(3):567-575.
  • 5Nguyen TD, Spincemaille P, Cham MD, et al. Free-breath- ing 3-dimensional steady-state free precession coronary mag- netic resonance angiography : comparison of four navigator ga- ting techniques [ J ]. Magn Reson Imaging, 2009, 27 (6) : 807-814.
  • 6Kolmogorov V, Nguyen TD, Nuval A, et al. Multiprocessor scheduling implementation of the simultaneous multiple vol- ume (SM:) navigator method [ J ]. Magn Reson Med, 2004, 52(2) :362-367.
  • 7Wang :, Vidan E, Bergman GW, et al. Cardiac motion of coronary arteries: variability in the rest period and implica- tions for coronary MR angiography [ J ]. Radiology, 1999, 213(3) :751-758.
  • 8B:rnert P, Stuber M, Botnar RM, et al. Comparison of fat suppression strategies in 3D spiral coronary magnetic reso- nance angiography [J]. J Magn Reson Imaging, 2002, 15 (4) :462-464.
  • 9Fayad ZA, Fuster V, FaUon JT, et al. Noninvasive in vivo human coronary artery lumen and wall imaging using black- blood magnetic resonance imaging [ J ]. Circulation, 2000,102(5) :506-510.
  • 10Kim WY, Stuber M, Barnett P, et al. Three-dimensional black-blood cardiac magnetic resonance coronary vessel wall imaging detects positive arterial remodeling in patients with nonsignificant coronary artery disease [ J ]. Circulation, 2002, 106(3) :296-299.

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部