摘要 综述了并行成像线圈的优化设计方法及其发展,并对其进行了比较、分析与展望。 In this paper,an overview is given on the optimization methods of designing RF coil array.And advantages and disadvantages are also discussed.
出处 《中国医疗器械杂志》 CAS 2010年第6期434-435,共2页 Chinese Journal of Medical Instrumentation
关键词 并行成像 磁共振线圈 优化设计 parallel imaging MRI coil optimization
  • 相关文献

参考文献12

  • 1Hutchinson M, Raff. Fast MRI data acquisition using multiple detectors[J]. Magn Reson Med, 1998,6:87.
  • 2J. R. Kelton, R. L. Magin, S. M. Wright. An algorithm for rapid image acquisition using multiple receive coil[A]. Eighth annual Meeting, SMRM, Amsterdam[C]. Netherlands, 1989,1172.
  • 3Kwait D, Einav S. A decoupled coil detector array for fast image acquisition in magnetic resonance imaging[J]. Med Phys, 1991,18:251.
  • 4Sodickson DK, Manning WJ. Simultaneous acquisition of spatial harmonics (SMASH): ultra-fast imaging with radiofrequency coil arrays[J]. Magn Reson Med, 1997,38:591.
  • 5Pruessmam KP, Weiger M, Scheidegger MB et al. SENSE: sensitivity encoding for fast MR1. Magn Reson Med, 1999,42:952.
  • 6Weiger M, Pruessmann C L, Leussler C, et al. Specific coil design for SENSE: a six-element cardiac array[J]. Magn Resort Med, 2001,45:495.
  • 7Lifters A, Quick H H, Herborn C U, et al. Geometrical optimization of a phased array coil for high-resolution MR imaging of the carotid arteries[J]. Magn Reson Med, 2003,50:439.
  • 8Dodd S J, Merkle H, Van Gelderen P, et al. A 4-channel SENSE optimized array coil for rodent brain imaging at 11.7 T. Proc[J]. Int Soc Magn Reson Med, 2005, (13): 913.
  • 9Lawrence B G, Crozier S, Cowin Get al. An inverse design of an open, head/neck RF coil for MRI[J]. IEEE Trans Biomed Eng, 2002,49:1024.
  • 10Xu B, Wei Q, Liu F and Crozier S. An inverse methodology for high frequency RF coil design for MRI with de-emphasized BI fields[J].IEEE Trans Biomed Eng, 2005, 52:1582.

同被引文献38

  • 1刘新球,刘铁芳,高登发.下肢磁共振成像技术的研究[J].医疗卫生装备,2007,28(2):61-62. 被引量:3
  • 2Wiart J. Hadjem A, Wong MF, et al. Analysis of RF exposure in the head tissues of children and adults[J]. Phys Med Biol, 2008, 53(I 3): 3681-3695.
  • 3Muranaka H, Horiguchi T, Usui S. et al. Dependence of RF heatting on SAR and implant position in'a 1.5T MR system[J]. Magn ResonMed Sci, 2007, 6(4): 199-209.
  • 4Boss A, Graf H. Berger A, Lauer UA, et al. Tissue wanning and regulatory responses induced by radio frequency energy deposition on a whole-body 3-Tesla magnetic resonance imager[J]. J Magn Reson Imaging. 2007, 26(5): 1334-1339.
  • 5谢寰彤.核磁共振磁体设备,中国:01276446[P].2002-10—23.
  • 6MARKHAACKEE.BROWNRW,THOMPSONMR,等.曾晓庄,包尚联主译.核磁共振成像原理和脉冲序列设计[M].北京:中国医药科技出版社,2007:1-555.
  • 7谢寰彤.磁共振成像用的自屏蔽梯度线圈:中国,CN202189140U[P].2012-04-11.
  • 8于曰俊,张国华,侯金文.磁共振并行采集技术的临床应用[J].中国中西医结合影像学杂志,2007,5(5):366-368. 被引量:5
  • 9杨正汉,冯逢,王霄英磁共振成像技术指南一检查规范、临床策略及新技术应用.北京:人民军医出版社.2007,234-252.
  • 10GOLOSHEVSKY A G, WALTON J H, SHUTOV M V, etal. Development of low field nuclear magnetic resonance mi-crocoils [J] Sev Sci Instrum,2005,76(2) :024101.