摘要 At the limited roof north-south (N-S) width of a building, for the array with multirow collectors based on no shading at winter solstice noon and sloped at latitude, this paper studied the shading and the radiant energy striking on solar collector array. Based on Kunming solar radiation data, the annual and monthly solar radiant energy striking on multi-array collectors was analyzed and estimated, from no shading to partial shading by adding 1-3 collector row, at the slopes of 10°, 15°, 20°, 25°, 30°, 35° and 40°, respectively. The results showed that properly increasing the row number by reducing the slope of collectors was reasonable in order to get more annual radiant energy. Adding 1 row at 10° of slope was economical for Kunming, based on the 5-row array at 25°. And adding collector row by 20% at 10° of slope could increase the radiant energy striking on the array by 19%. At the limited roof north-south (N-S) width of a building, for the array with multirow collectors based on no shading at winter solstice noon and sloped at latitude, this paper studied the shading and the radiant energy striking on solar collector array. Based on Kunming solar radiation data, the annual and monthly solar radiant energy striking on multi-array collectors was analyzed and estimated, from no shading to partial shading by adding 1-3 collector row, at the slopes of 10°, 15°, 20°, 25°, 30°, 35° and 40°, respectively. The results showed that properly increasing the row number by reducing the slope of collectors was reasonable in order to get more annual radiant energy. Adding 1 row at 10° of slope was economical for Kunming, based on the 5-row array at 25°. And adding collector row by 20% at 10° of slope could increase the radiant energy striking on the array by 19%.
出处 《Journal of Northeast Agricultural University(English Edition)》 CAS 2010年第4期76-82,共7页 东北农业大学学报(英文版)
关键词 limited roof width solar water heating system multirow collector array optimizing design limited roof width, solar water heating system, multirow collector array, optimizing design
  • 相关文献

参考文献7

  • 1Duffie J A,Beckman W A.Solar engineering of thermal processes[M].3nd ed.[S.I.]:John Wiley&Sons,Inc,2004.
  • 2Cooper P 1.The absorption of solar radiation in solar stills[J].Solar Energy,1969,12(3):333-346.
  • 3Erbs D G,Klein S A,Duffle J A.Estimation of the diffuse radiation fraction for hourly,daily,and monthly-average global radiation[J].Solar Energy,1982,28(4):293-302.
  • 4Collares-Pereira M,Rabl A.The average distribution of solar radiation:correlations between diffuse and hemispherical and between daily and hourly isolation values[J].Solar Energy,1979,22(2):155-164.
  • 5Liu B Y H,Jordan R C.The interrelationship and characteristic distribution of direct,diffuse and total solar radiation[J].Solar Energy,1960,4(3):1-19.
  • 6Liu B Y H,Jordan R C.The long-term average performance of flatplate solar energy collectors[J].Solar Energy,1963,7(2):53-74.
  • 7Chen Z Y.Climate pandect of Yunnan Province[M].Beijing:China Meteorological Press,2001:47-52.(in Chinese).