期刊文献+

Diagnostic value of contrast-enhanced intraoperative Doppler sonography for cerebral arteriovenous malformations compared with angiography 被引量:6

Diagnostic value of contrast-enhanced intraoperative Doppler sonography for cerebral arteriovenous malformations compared with angiography
原文传递
导出
摘要 Background Intraoperative Doppler sonography has been used in the neurosurgical operating room for the localization and description of cerebral arteriovenous malformations (AVMs). This study aimed to investigate the clinical value of contrast-enhanced intraoperative Doppler sonography, including its ability to assess the location and identify of feeding arteries in patients with AVMs and to compare this method with angiography.Methods Twenty-three patients with cerebral AVMs who were diagnosed using angiography, were examined with contrast-enhanced intraoperative Doppler sonography. As an echo-enhancing agent, Sulphur Hexafluoride Microbubbles for Injection ("SonoVue") was administered intravenously in all patients. Sonogram results were reviewed and correlated with angiographic findings. For statistical analysis, the Wilcoxon signed-rank test was applied.Results Angiography identified 20 AVM lesions in the anterior or middle fossa and 3 in the posterior fossa.Contrast-enhanced intraoperative Doppler was somewhat less sensitive for only detecting 21/23 (91.3%) of the AVM lesions. Additionally, contrast-enhanced intraoperative Doppler slightly underestimated AVM size compared with angiographic findings but showed feeding arteries with sufficient acoustic properties. In 15 patients, angiography revealed a coincidental blood supply from another intracranial vessel, which was missed by contrast-enhanced intraoperative Doppler sonography.Conclusions In a limited group of patients with AVMs, contrast-enhanced intraoperative Doppler sonography was a less sensitive but useful and simple method for the detection of AVMs in contrast to angiography. No specific untoward effects were attributed to the use of "SonoVue" as a contrast-enhancing substance. Background Intraoperative Doppler sonography has been used in the neurosurgical operating room for the localization and description of cerebral arteriovenous malformations (AVMs). This study aimed to investigate the clinical value of contrast-enhanced intraoperative Doppler sonography, including its ability to assess the location and identify of feeding arteries in patients with AVMs and to compare this method with angiography.Methods Twenty-three patients with cerebral AVMs who were diagnosed using angiography, were examined with contrast-enhanced intraoperative Doppler sonography. As an echo-enhancing agent, Sulphur Hexafluoride Microbubbles for Injection ("SonoVue") was administered intravenously in all patients. Sonogram results were reviewed and correlated with angiographic findings. For statistical analysis, the Wilcoxon signed-rank test was applied.Results Angiography identified 20 AVM lesions in the anterior or middle fossa and 3 in the posterior fossa.Contrast-enhanced intraoperative Doppler was somewhat less sensitive for only detecting 21/23 (91.3%) of the AVM lesions. Additionally, contrast-enhanced intraoperative Doppler slightly underestimated AVM size compared with angiographic findings but showed feeding arteries with sufficient acoustic properties. In 15 patients, angiography revealed a coincidental blood supply from another intracranial vessel, which was missed by contrast-enhanced intraoperative Doppler sonography.Conclusions In a limited group of patients with AVMs, contrast-enhanced intraoperative Doppler sonography was a less sensitive but useful and simple method for the detection of AVMs in contrast to angiography. No specific untoward effects were attributed to the use of "SonoVue" as a contrast-enhancing substance.
出处 《Chinese Medical Journal》 SCIE CAS CSCD 2010年第20期2812-2815,共4页 中华医学杂志(英文版)
关键词 arteriovenous malformations intraoperative ultrasonography ultrasound contrast agent arteriovenous malformations intraoperative ultrasonography ultrasound contrast agent
  • 相关文献

参考文献1

二级参考文献7

  • 1周大彪,赵继宗,王硕,倪明,王嵘,张东,赵元立.术中实时超声在脑动静脉畸形外科治疗中的应用[J].中华医学杂志,2005,85(24):1688-1691. 被引量:25
  • 2Spetzler RF,Martin NA.Aproposed grading system of arteriovenous malformations[J].J Neurosurg,1986,65:476-480
  • 3Cokluk C,Lyigun O,Senel A,et al.The guidance of intraoperative ultrasonography in the surgical treatment of arteriovenous malformation[J].Minim Invasive Neurosurg,2003,46:169-172
  • 4Gronningsaeter A,Klevev A,Ommedal S,et al.Sono Wand an ultrasoundbased neuronavigation system[J].Neurosurgery,2000,47:1373-1379
  • 5Dempsey RJ,Moftakhar R,Pozniak M.Intraoperative doppler to measure cerebrovascular resistance as a guide to complete resection of arteriovenous malformations[J].Neurosurgery,2004,55:155-161
  • 6Nagelhus HTA,Ommedal S,Lie T,et al.Stereoscopic navigation-controlled display of preoperative MRI and intraoperative 3D ultrasound in planning and guidance of neurosurgery:New technology for minimally invasive image-guided surgery approaches[J].Minim Invasive Neurosurg,2003,46:129-137
  • 7庄磊,段云友,曹铁生,阮骊韬.经颅能量多普勒血流显像在脑动静脉畸形诊断中的价值[J].中华超声影像学杂志,2000,9(5):300-302. 被引量:5

共引文献6

同被引文献23

引证文献6

二级引证文献63

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部