期刊文献+

多层螺旋CT在法洛四联症解剖畸形及心功能评价中的应用价值探讨 被引量:1

Value of MSCT in the evaluation of anatomical and ventricular functional changes in tetralogy of fallot patients
暂未订购
导出
摘要 目的探讨多层螺旋CT(MSCT)在法洛四联症(TOF)患者解剖及心功能改变评价中的应用价值。方法 32例经手术证实的TOF患者,术前均行MSCT和超声心动图(UCG)检查。以手术结果为标准,比较MSCT、UCG对TOF患者解剖畸形显示的正确率。比较MSCT、UCG测得的心室功能指标。结果 MSCT对TOF的诊断准确率为100%,对合并畸形的显示正确率为88.2%(30/34),主要漏诊为心内畸形,MSCT测量的右室流出道(RVOT)、肺动脉干(MPA)、右肺动脉(RPA)起始处、左肺动脉(LPA)起始处、VSD的直径及骑跨率、左室射血分数(LVEF)与UCG测量结果差异无显著性,测得的左室舒张末期容积(LVEDV)大于UCG测量结果,但二者有显著的相关性。结论 MSCT是评价TOF患者解剖畸形及心室功能改变的良好无创性检查方法。 Objective To investigate the value of MSCT to evaluate anatomical and ventricular functional changes in tetralogy of fallot(TOF) patients.Methods 32 cases of TOF were collected which were proved by surgery in our hospital and underwent MSCT and ultrasonic cardiogram(UCG) before operation.Then the results of sugery were taken as stantard,and the accuracy of the display of anatomic abnormalities and the measurement of ventricular function in the patients with TOF was evaluated.Results The diagnositc accuracy of MSCT in TOF was 100%,in TOF combined with abnormalities was 88.2%(30/34) and the missed diagnoses were mainly endocardial malformation.The metered results of MSCT in RVOT,MPA,the origin of RPA and LPA,the diameter of VSD,the ride-step rate and LVEF were not significantly different from that of UCG.The result of LVEDV measured by MSCT was larger than that by UCG,but there were significant correlation between them.Conclusion MSCT is a good noninvasive method for the evaluation of anatomical and ventricular functional changes of patients with TOF.
出处 《山东医药》 CAS 北大核心 2010年第38期1-3,共3页 Shandong Medical Journal
基金 黑龙江省卫生厅科研基金资助项目(2009-069)
关键词 法洛四联症 X线计算机体层摄影 超声心动图 tetralogy of fallot X-ray computed tomography ultrasonic cardiogram
  • 相关文献

参考文献3

二级参考文献22

  • 1黄美萍,梁长虹,曾辉,刘其顺,张忠林,张金娥,黄飚.新生儿及婴儿先天性心脏病多层螺旋CT心血管成像[J].中国医学影像技术,2004,20(7):1060-1063. 被引量:24
  • 2张雪莲,王巧兮,马兵毅,陈艳,彭志远,陈险峰,孙庆军.多层螺旋CT在诊断法洛四联症中的应用[J].中国介入影像与治疗学,2006,3(6):425-427. 被引量:8
  • 3Tsai IC, Lee T, Chen MC, et al. Visualization of neonatal coronary arteries on multidetector row CT: ECG-gated versus non-ECG-gated technique. Pediatr Radiol, 2007,37(8) :818-825.
  • 4Goo HW, Park IS, Ko JK, et al. Visibility of the origin and proximal course of coronary arteries on non-ECG-gated heart CT in patients with congenital heart disease. Pediatr Radiol, 2005,35(8): 792-798.
  • 5Pannu HK, Flohr TG, Corl FM, et al. Current concepts in multidetector row CT evaluation of the coronary arteries; principles, techniques, and anatomy. Radiographics, 2003,23:S111-125.
  • 6Angelini P, Velasco JA, Flamm S. Coronary anomalies: incidence, pathophysiology, and clinical relevance. Circulation, 2002, 105(20) :2449-2454.
  • 7Dabizzi RP, Teodori G, Barletta GA, et al. Associated coronary and cardiac anomalies in the tetralogy of Fallot: an angiographic study. Eur Heart J, 1990,11(8) :692-704.
  • 8Carvalho JS, Silva CMC, Rigby ML, et al. Angiographie diagnosis of anomalous coronary artery in tetralogy of Fallot. Br Heart J, 1993,70 (1) : 75-78.
  • 9Sutton N, Lock JE, Geggel RL. Cardiac catheterization in infants weighing less than 1, 500 grams. Catheter Cardiovasc Interv, 2006,68(6) :948-956.
  • 10Vitielto R, McCrindle BW, Nykanen D, et al. Complications associated with pediatric cardiac catheterization. J Am Coll Cardiol, 1998,32(5) : 1433-1440.