当用最小偏向角法测量棱镜材料折射率时,因不满足充要条件而导致错误的测量值,本文介绍一种修正方法。
This article has introduced a correcting method to deal with erroneous measured value be-cause of lack of some necessary requirements when the angle of minimum deviation is used to mea-sure index of refraction of the prism.
出处
《上海工程技术大学学报》
CAS
1999年第1期78-80,共3页
Journal of Shanghai University of Engineering Science
关键词
实验
测量值
棱镜
折射率
色散关系
Experiment Measured values Prism lens Refractive index