期刊文献+

APD光子计数图像的蒙特卡洛仿真与实现 被引量:1

Monte Carlo Simulation and Implementation of Photon Counting Image Based on APD
在线阅读 下载PDF
导出
摘要 该文应用统计光学理论研究微光成像;结合雪崩光电二极管(APD)光子探测器件的工作特点,采用蒙特卡洛方法模拟光子计数图像的成像过程。结果表明,通过基于器件特性和光子运动统计规律的仿真实验可以获得光子计数图像。以仿真流程为依据搭建了固态APD光子计数成像实验系统。在10-5lx环境照度下,通过对目标扫描得到一系列光子计数值。将光子计数数据进行存储和运算,恢复了光子计数图像。实验证明,基于APD的成像系统可以实现微光环境下目标的二维探测成像。 The low light level(LLL) imaging is studied by means of the theory of statistical optics.The imaging process of the photon counting image is simulated by the Monte Carlo method and combining the working characteristics of the avalanche photodiode(APD) photon detector.The results indicate that the photon counting image can be obtained by the simulation experiments which make use of the performances of the APDs and statistical law of the motion of the photons.The photon counting imaging experimental system is built based on the simulation flow.A series of photon counting values is obtained by scanning the target at 10-5lx.The data of photon counting are stored and calculated to get the photon counting images.The experimental results prove that the 2-dimensional imaging detection can be implemented based on the APDs in the low light level conditions.
出处 《南京理工大学学报》 EI CAS CSCD 北大核心 2010年第5期649-652,共4页 Journal of Nanjing University of Science and Technology
基金 江苏省自然科学基金(BK2008049) 教育部博士点基金(20070288011) 南京理工大学自主科研专项计划资助项目(2010ZYTS033)
关键词 成像系统 雪崩光电二极管 光子计数 imaging systems avalanche photodiodes photon counting
  • 相关文献

参考文献1

二级参考文献16

  • 1陈天明,俞信,王苏生.超微弱发光图像的统计处理方法[J].光学学报,1996,16(8):1152-1156. 被引量:7
  • 2A. Boksenberg, D. E. Burgess. Image photon counting system for optical astronomy. Adv. Electron and Electron Physics, 1972,33B:835-849.
  • 3J.L.A. Fordham, et al. Astronomical performance of a micro - channel plateinstensified photon counting detector. Mon. Not. R. Astr. Soc., 1989, 237:513 - 521.
  • 4R.W. Aircy,et al. DQE enhancement of MCP intensifiers for astronomy results of the MIC Ⅱ programme. Proc. SPIE, 1990,1235 : 338 - 346.
  • 5Yutaka Tsuchiya,et al. photon counting image acquisition system and its applications. J. Imaging Technol, 1985,11:215 - 220.
  • 6J.G. Timothy,J. S. Morgan,et al. MaMa detector system:A status report. Proc. SPIE, 1989,1158 : 104 - 117.
  • 7D.B. Kasle,J. S. Morgan. High resolution decoding of multi - anade microchannel array detector. Proc. SPIE, 1991,1549:52 - 58.
  • 8J. Sebay, G. Lelievre. Wavefront sensing and deconvolution of turbulence - degraded photon - counting images. Proc. SPIE, 1993, 1982:368-372.
  • 9F. Fiddouh, et al. Real - time photo centroid detection for photon counting and wavefront sensing camera. SPI, 1993,1982 Photoelectronic Detection: 288 - 292.
  • 10Genrui Cao,Xin. Yu. Accuracy analysis of a Hartmann - Shack wavefront sensor operated with a faint object. Proc. SPIE, 1994, 33 : 2331 - 2335.