期刊文献+

恒电量技术监测聚合磷酸盐操作效果的研究

MONITURING THE EFFECTION OF PLOYPHOSPHATE IN COOLING WATER TREATMENT SYSTEM BY THE COULOSTATIC METHOD
在线阅读 下载PDF
导出
摘要 运用恒电量技术对使用聚合磷酸盐配方的冷却水系统进行腐蚀监测,通过Rp、Rf等参数的分析来研究影响操作效果的主要因素.能随时报道膜层的生长和维持情况,灵敏地反映水处理各阶段的腐蚀变化. By a coulostatic perturbation meter and a computer as on line measurement system, the corrosion behaving of cooling water was monitored. Based on the analysis of E t attenuation curves, relevant parameters, R p and R f in equivalent circuit for the system, were obtained. Thus the factors which affect the application effect of ployphosphate in the treatment of circulation cooling water were studied, so the situation of film forming could be reported at all time, the corrosion of the systems could be also monitored sensitively.
出处 《腐蚀科学与防护技术》 CAS CSCD 1999年第2期118-121,共4页 Corrosion Science and Protection Technology
基金 金属腐蚀与防护国家重点实验室 化工部科技司基金
关键词 恒电量 腐蚀监测 聚合磷酸盐 冷却水 水处理 coulostatic, cooling water, ployphosphate, corrosion monitoring