期刊文献+

二甲醚替代CFC12的电冰箱模拟计算和实验研究 被引量:6

Simulating Calculation and Experimental Study onthe Refrigerator with Substituting Dimethylether for CFC12
在线阅读 下载PDF
导出
摘要 以PR状态方程为依据,分别对CFC12和二甲醚(DME)进行了电冰箱理论制冷循环模拟计算和对比试验。试验结果表明,在不改变原冰箱结构条件下,用DME替代CFC12是可行的;在DME最佳充灌量(80g)下,耗电量为1.435kW·h/24h,较原机铭牌额定耗电量(1.45kW·h24/h)降低1.03%;为开发无氟绿色冰箱提供了一个新途径。 This paper presents a simulated calculation of the refrigerator's theoretical refrigeration cycle in with CFC12 and DME by PR state equation,and an experiment study of CFC12 in contrast to DME in the refrigerator.The results of experiment proved that it is feasible to substitute DME for CFC12 on the condition of no change of the structure of the refrigerator. On the condition of the fittest amoumt of refrigerant by the use of DME (80g).The energy consumption is 1.435 kW·h/24h,and decreases by 1.03% compared with the rated energy consumption (1.450 kW.h/24h)of the original refrigerator,and it offers a new way for developing refrigerator of environmental protection.
出处 《重庆建筑大学学报》 CSCD 1999年第3期50-55,共6页 Journal of Chongqing Jianzhu University
关键词 二甲醚 电冰箱 替代工质 制冷循环模拟 dimethyl ether(DME) refrigerator alternative refrigerant
  • 相关文献

参考文献6

  • 1国家技术监督局发布,GB/T8059-1995家用制冷器具冷藏冷冻箱,1996年
  • 2苏长荪,高等工程热力学,1987年
  • 3汪巩,有机化学,1985年
  • 4童景山,流体热物理性质的计算,1982年
  • 5国家技术监督局发布,GB9098-88电冰箱用全封闭电动机-压缩机
  • 6四川成都华菱化工有限责任公司,二甲醚产品介绍

同被引文献45

引证文献6

二级引证文献53