介绍了变风量系统新风量控制中的风阀控制、送回风机控制、独立设置风机、混合段静压控制、CO2浓度控制和人数估计控制等方法,分析了各种方法的特点和应用范围。
Describes the methods used in outside air control in VAV systems including those of damper regulating, supply and return fans, additional outdoor air fans, static pressure in the mixed section, CO 2 concentration and estimated occupancy, as well as the characteristics and applicability of each of them.